Risk factors of instrumentation failure after laminectomy and posterior cervical fusions (PCF)

Author:

Chen Zejun,Lv Guohua,Zhang Ou,Li Yunchao,Wang Xiaoxiao,He Haoyu,Yuan Hui,Pan Changyu,Kuang Lei

Abstract

Abstract Background For patients with multilevel degenerative cervical myelopathy, laminectomy and posterior cervical fusions (PCF) with instrumentation are widely accepted techniques for symptom relief. However, hardware failure is not rare and results in neck pain or even permanent neurological lesions. There are no in-depth studies of hardware-related complications following laminectomy and PCF with instrumentation. Methods The present study was a retrospective, single centre, observational study. Patients who underwent laminectomy and PCF with instrumentation in a single institution between January 2019 and January 2021 were included. Patients were divided into hardware failure and no hardware failure group according to whether there was a hardware failure. Data, including sex, age, screw density, end vertebra (C7 or T1), cervical sagittal alignment parameters (C2-C7 cervical lordosis, C2-C7 sagittal vertical axis, T1 slope, Cervical lordosis correction), regional Hounsfield units (HU) of the screw trajectory and osteoporosis status, were collected and compared between the two groups. Results We analysed the clinical data of 56 patients in total. The mean overall follow-up duration was 20.6 months (range, 12–30 months). Patients were divided into the hardware failure group (n = 14) and no hardware failure group (n = 42). There were no significant differences in the general information (age, sex, follow-up period) of patients between the two groups. The differences in fusion rate, fixation levels, and screw density between the two groups were not statistically significant (p > 0.05). The failure rate of fixation ending at T1 was lower than that at C7 (9% vs. 36.3%) (p = 0.019). The regional HU values of the pedicle screw (PS) and lateral mass screw (LMS) in the failure group were lower than those in the no failure group (PS: 267 ± 45 vs. 368 ± 43, p = 0.001; LMS: 308 ± 53 vs. 412 ± 41, p = 0.001). The sagittal alignment parameters did not show significant differences between the two groups before surgery or at the final follow-up (p > 0.05). The hardware failure rate in patients without osteoporosis was lower than that in patients with osteoporosis (14.3% vs. 57.1%) (p = 0.001). Conclusions Osteoporosis, fixation ending at C7, and low regional HU value of the screw trajectory were the independent risk factors of hardware failure after laminectomy and PCF. Future studies should illuminate if preventive measures targeting these factors can help reduce hardware failure and identified more risk factors, and perform long-term follow-up.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3