Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma

Author:

Ju Sang Gyu,Ahn Yong Chan,Kim Yeong-bi,Kim Jin Man,Kwon Dong Yeol,Park Byoung Suk,Yang Kyungmi

Abstract

Abstract Background To compare the dosimetric profiles of volumetric modulated arc therapy (VMAT) plans using the fast-rotating O-ring linac (the Halcyon system) based on a dual-layer stacked multi-leaf collimator and helical tomotherapy (HT) for nasopharyngeal cancer (NPCa). Methods For 30 NPCa patients, three sets of RT plans were generated, under the same policy of contouring and dose constraints: HT plan; Halcyon VMAT plan with two arcs (HL2arc); and Halcyon VMAT plan with four arcs (HL4arc), respectively. The intended dose schedule was to deliver 67.2 Gy to the planning gross target volume (P-GTV) and 56.0 Gy to the planning clinical target volume (P-CTV) in 28 fractions using the simultaneously integrated boost concept. Target volumes and organ at risks dose metrics were evaluated for all plans. Normal tissue complication probabilities (NTCP) for esophagus, parotid glands, spinal cord, and brain stem were compared. Results The HT plan achieved the best dose homogeneity index for both P_GTV and P_CTV, followed by the HL4arc and L2arc plans. No significant difference in the dose conformity index (CI) for P_GTV was observed between the HT plan (0.80) and either the HL2arc plan (0.79) or the HL4arc plan (0.83). The HL4arc plan showed the best CI for P_CTV (0.88), followed by the HL2arc plan (0.83) and the HT plan (0.80). The HL4arc plan (median, interquartile rage (Q1, Q3): 25.36 (22.22, 26.89) Gy) showed the lowest Dmean in the parotid glands, followed by the HT (25.88 (23.87, 27.87) Gy) and HL2arc plans (28.00 (23.24, 33.99) Gy). In the oral cavity (OC) dose comparison, the HT (22.03 (19.79, 24.85) Gy) plan showed the lowest Dmean compared to the HL2arc (23.96 (20.84, 28.02) Gy) and HL4arc (24.14 (20.17, 27.53) Gy) plans. Intermediate and low dose regions (40–65% of the prescribed dose) were well fit to the target volume in HL4arc, compared to the HT and HL2arc plans. All plans met the dose constraints for the other OARs with sufficient dose margins. The between-group differences in the median NTCP values for the parotid glands and OC were < 3.47% and < 1.7% points, respectively. Conclusions The dosimetric profiles of Halcyon VMAT plans were comparable to that of HT, and HL4arc showed better dosimetric profiles than HL2arc for NPCa.

Funder

National Research Foundation of Korea

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3