Prostate deformation during hypofractionated radiotherapy: an analysis of implanted fiducial marker displacement

Author:

Knybel Lukas,Cvek JakubORCID,Blazek Tomas,Binarova Andrea,Parackova Tereza,Resova Kamila

Abstract

Abstract Background To report prostate deformation during treatment, based on an analysis of fiducial marker positional differences in a large sample. Material and methods This study included 144 patients treated with prostate stereotactic body radiation therapy after implantation in each of 4 gold fiducial markers (FMs), which were located and numbered consistently. The center of mass of the FMs was recorded for every pair of X-ray images taken during treatment. The distance between each pair of fiducials in the live X-ray images is calculated and compared with the respective distances as determined in the CT volume. The RBE is the difference between these distances. Mean RBE and intrafraction and interfraction RBE were evaluated. The intrafraction and intefraction RBE variability were defined as the standard deviation, respectively, of all RBE during 1 treatment fraction and of the mean daily RBE over the whole treatment course. Results We analyzed 720 treatment fractions comprising 24,453 orthogonal X-ray image acquisitions. We observed a trend to higher RBE related to FM4 (apex) during treatment. The fiducial marker in the prostate apex could not be used in 16% of observations, in which RBE was > 2.5 mm. The mean RBEavg was 0.93 ± 0.39 mm (range 0.32–1.79 mm) over the 5 fractions. The RBEavg was significantly lower for the first and second fraction compared with the others (P < .001). The interfraction variability of RBEavg was 0.26 ± 0.16 mm (range 0.04–0.74 mm). The mean intrafraction variability of all FMs was 0.45 ± 0.25 mm. The highest Pearson correlation coefficient was observed between FM2 and FM3 (middle left and right prostate) (R = 0.78; P < .001). Every combination with FM4 yielded lower coefficients (range 0.66–0.71; P < .001), indicating different deformation of the prostate apex. Conclusions Ideally, prostate deformation is generally small, but it is very sensitive to rectal and bladder filling. We observed RBE up to 11.3 mm. The overall correlation between FMs was affected by shifts of individual fiducials, indicating that the prostate is not a “rigid” organ. Systematic change of RBE average between subsequent fractions indicates a systematic change in prostate shape.

Funder

Ministerstvo Zdravotnictví Ceské Republiky

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3