Safety and efficacy of fiducial marker implantation for robotic stereotactic body radiation therapy with fiducial tracking

Author:

Scher NathanielORCID,Bollet Marc,Bouilhol Gauthier,Tannouri Remi,Khemiri Imane,Vouillaume Aurelie,Sellami Noura,Von Eyben Rie,Vannetzel Jean-Michel,Darmon Ilan,Rotenberg Luc,Lamallem Hanah,Bauduceau Olivier,Foster Denis,Toledano Alain

Abstract

Abstract Purpose The purpose of this study was to assess the feasibility, efficacy and toxicity of fiducial marker implantation and tracking in CyberKnife® stereotactic radiation therapy (SBRT) applied to extracranial locations. Materials and method This is a retrospective, single-centre, observational study to collect the data of all patients treated by stereotactic radiation therapy with fiducial marker tracking at extracranial locations, conducted between June 2014 and November 2017. Information regarding the implantation procedure, the types of toxicity related to marker implantation and the number of markers implanted/tracked during treatment were collected. Complication rates were evaluated using the CTCAE v4 [Common Terminology Criteria for Adverse Events] scale. The technical success rate was based on the ability to optimally track the tumor throughout all treatment fractions. Results Out of 2505 patients treated by stereotactic radiation therapy, 25% received treatment with fiducial marker tracking. The total number of implantation procedures was 616 and 1543 fiducial markers were implanted. The implantation-related complication rate was 3%, with 16 Grade 1 events and 4 Grade 2 events. The number of treated patients and the number of implanted markers has gradually increased since the technique was first implemented. The median treatment time was 27 min (range 10–76). 1295 fiducials were effectively tracked throughout all treatment fractions, corresponding to a technical success rate of 84%. The difference between the number of fiducials implanted and those tracked during treatment decreased significantly as the site’s experience increased. Conclusion Fiducial marker implantation and tracking is feasible, well-tolerated, and technically effective technique in SBRT for extracranial tumors.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3