Evaluation of a new foetal shielding device for pregnant brain tumour patients

Author:

Kang Seonghee,Kim Kyeong-Hyeon,Kang Sang-Won,Shin Dong-Seok,Lee Seungwan,Chung Jin-Beom

Abstract

Abstract Background The present study aimed to propose a new foetal shielding device for pregnant cancer patients to reduce the foetal dose associated with treatment techniques using multiple gantry angles, such as intensity-modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT). Methods Three shielding structures were designed to minimise the scattered and leaked radiation from various gantry angles and radiation scattering within the patient. The base-plate part that can be placed on the treatment couch was designed to reduce the scattered and leaked radiation generated at gantry angles located near 180°. A body shielding part that can cover the lower chest and abdomen was designed, and a neck-shielding structure was added to reduce the internal and external radiation scattering from the treatment area. Evaluation plans were generated to assess the foetal dose reduction by the foetal shielding device in terms of the shielding material thickness, distance from the field edge, and shielding component using the flattened 6 MV photon beam (6MV) and flattening filter-free 6 MV photon beam (6MV-FFF). In addition, the effectiveness of the foetal shielding device was evaluated in a pregnant brain tumour patient. Results The shielding material consisting of three parts was placed on frames composed of four arch shapes with a vertical curved structure, connection bar at the top position, and base plate. Each shielding part resulted in reductions in the radiation dose according to the treatment technique, as the thickness of the shielding material increased and the foetal dose decreased. In addition, a foetal dose reduction of approximately 50% was confirmed at 50 cm from the field edge by using the designed shielding device in most delivery techniques. In patients, the newly designed shielding structures can effectively eliminate up to about 49% of the foetal dose generated from various gantry angles used in VMAT or IMRT. Conclusions We designed a foetal shielding device consisting of three parts to effectively reduce the dose delivered to the foetus, and evaluated the device with various treatment techniques for a pregnant patient with brain tumour. The foetal shielding device shielded the scattered/leaked radiation from the treatment machine, and also effectively reduced internal scattering from the treatment area in the patient.

Funder

National Research Foundation of Korea

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging,Oncology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3