Feasibility of dose calculation for treatment plans using electron density maps from a novel dual-layer detector spectral CT simulator

Author:

Zhu Qizhen,Wei Shuoyang,Wang Zhiqun,Xu Haoran,Zhou Bing,Qu Huiying,Nie Mingming,Guo Ning,Wang Wenshuai,Yang Bo,Qiu Jie

Abstract

Abstract Background Conventional single-energy CT can only provide a raw estimation of electron density (ED) for dose calculation by developing a calibration curve that simply maps the HU values to ED values through their correlations. Spectral CT, also known as dual-energy CT (DECT) or multi-energy CT, can generate a series of quantitative maps, such as ED maps. Using spectral CT for radiotherapy simulations can directly acquire ED information without developing specific calibration curves. The purpose of this study is to assess the feasibility of utilizing electron density (ED) maps generated by a novel dual-layer detector spectral CT simulator for dose calculation in radiotherapy treatment plans. Methods 30 patients from head&neck, chest, and pelvic treatment sites were selected retrospectively, and all of them underwent spectral CT simulation. Treatment plans based on conventional CT images were transplanted to ED maps with the same structure set, including planning target volume (PTV) and organs at risk (OARs), and the dose distributions were then recalculated. The differences in dose and volume histogram (DVH) parameters of the PTV and OARs between the two types of plans were analyzed and compared. Besides, gamma analysis between these plans was performed by using MEPHYSTO Navigator software. Results In terms of PTV, the homogeneity index (HI), gradient index (GI), D2%, D98%, and Dmean showed no significant difference between conventional plans and ED plans. For OARs, statistically significant differences were observed in parotids D50%, brainstem in head&neck plans, spinal cord in chest plans and rectum D50% in pelvic plans, whereas the variance remained minor. For the rest, the DVH parameters exhibited no significant difference between conventional plans and ED plans. All of the mean gamma passing rates (GPRs) of gamma analysis were higher than 90%. Conclusion Compared to conventional treatment plans relying on CT images, plans utilizing ED maps demonstrated similar dosimetric quality. However, the latter approach enables direct utilization in dose calculation without the requirements of establishing and selecting a specific Hounsfield unit (HU) to ED calibration curve, providing an advantage in clinical applications.

Funder

The China National Key R&D Program during the 14th Five-year Plan Period

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3