Per-fraction positional and dosimetric performance of prone breast tangential radiotherapy on Halcyon™ linear accelerator assessed with daily rapid kilo-voltage cone beam computed tomography: a single-institution pilot study

Author:

Yoon Suk W.ORCID,Taunk Neil K.,Freedman Gary M.,Hubley Emily,O’Reilly Shannon,Teo Boon- Keng K.,Anamalayil Shibu,Dong Lei,Kennedy Christopher,Zou Wei,Metz James M.,Li Taoran

Abstract

Abstract Background This study investigates daily breast geometry and delivered dose to prone-positioned patients undergoing tangential whole breast radiation therapy (WBRT) on an O-ring linear accelerator with 6X flattening filter free mode (6X-FFF), planned with electronic compensation (ECOMP) method. Most practices rely on skin marks or daily planar image matching for prone breast WBRT. This system provides low dose daily CBCT, which was used to study daily robustness of delivered dose parameters for prone-positioned WBRT. Methods Eight patients treated with 16-fraction prone-breast WBRT were retrospectively studied. Planning CTs were deformed to daily CBCT to generate daily synthetic CTs, on which delivered dose distributions were calculated. A total of 8 × 16 = 128 synthetic CTs were generated. Consensus ASTRO definition was used to contour Breast PTV Eval for each daily deformed CT. Breast PTV Eval coverage (V90%) and hotspot (V105% and Dmax) were monitored daily to compare prescription dose with daily delivered dose. Various predictors including patient weight, breast width diameter (BWD), and Dice similarity coefficient (DSC) were fit into an analysis of covariance model predicting V90% and V105% deviation from prescribed (ΔV90%, ΔV105%). Statistical significance is indicated with asterisks (* for p < 0.05; ** for p < 0.001). Results Daily delivered Breast PTV Eval V90% was moderately smaller than prescribed (median ΔV90% = − 0.1%*), while V105% was much larger (median ΔV105% = + 10.1%** or + 92.4 cc**). Patient’s weight loss correlated with significantly increased ΔV105% (+ 4.6%/ − 1% weight, R2 = 0.4**) and moderately decreased ΔV90% (− 0.071%/ − 1% wt., R2 = 0.2**). Comprehensive ANCOVA models indicated three factors affect ΔV90% and ΔV105% the most: (1) BWD decrease (− 0.09%* and + 10%**/ − 1 cm respectively), (2) PTV Eval volume decrease (− 0.4%** and + 9%**/ − 100 cc), and for ΔV105% only, (3) the extent of breast deformation (+ 10%**/ − 0.01 DSC). Breast PTV Eval volume also decreased with time (− 2.21*cc/fx), possibly indicating seroma resolution and increase in V105% over time. Conclusions Daily CBCT revealed key delivered dose parameters vary significantly for patients undergoing tangential prone breast WBRT planned with ECOMP using 6X-FFF. Patient weight, BWD, and breast shape deformation could be used to predict dosimetric variations from prescribed. Preliminary findings suggest an adaptive plan based on daily CBCT could reduce excessive dose to the breast.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3