Fiducial-based image-guided SBRT for pancreatic adenocarcinoma: Does inter-and intra-fraction treatment variation warrant adaptive therapy?

Author:

Hill Colin S.,Han-Oh Sarah,Cheng Zhi,Wang Ken Kang-Hsin,Meyer Jeffrey J.,Herman Joseph M.,Narang Amol K.

Abstract

Abstract Purpose Variation in target positioning represents a challenge to set-up reproducibility and reliability of dose delivery with stereotactic body radiation therapy (SBRT) for pancreatic adenocarcinoma (PDAC). While on-board imaging for fiducial matching allows for daily shifts to optimize target positioning, the magnitude of the shift as a result of inter- and intra-fraction variation may directly impact target coverage and dose to organs-at-risk. Herein, we characterize the variation patterns for PDAC patients treated at a high-volume institution with SBRT. Methods We reviewed 30 consecutive patients who received SBRT using active breathing coordination (ABC). Patients were aligned to bone and then subsequently shifted to fiducials. Inter-fraction and intra-fraction scans were reviewed to quantify the mean and maximum shift along each axis, and the shift magnitude. A linear regression model was conducted to investigate the relationship between the inter- and intra-fraction shifts. Results The mean inter-fraction shift in the LR, AP, and SI axes was 3.1 ± 1.8 mm, 2.9 ± 1.7 mm, and 3.5 ± 2.2 mm, respectively, and the mean vector shift was 6.4 ± 2.3 mm. The mean intra-fraction shift in the LR, AP, and SI directions were 2.0 ± 0.9 mm, 2.0 ± 1.3 mm, and 2.3 ± 1.4 mm, respectively, and the mean vector shift was 4.3 ± 1.8 mm. A linear regression model showed a significant relationship between the inter- and intra-fraction shift in the AP and SI axis and the shift magnitude. Conclusions Clinically significant inter- and intra-fraction variation occurs during treatment of PDAC with SBRT even with a comprehensive motion management strategy that utilizes ABC. Future studies to investigate how these variations could lead to variation in the dose to the target and OAR should be investigated. Strategies to mitigate the dosimetric impact, including real time imaging and adaptive therapy, in select cases should be considered.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3