Quality assurance of radiotherapy in the ongoing EORTC 1420 “Best of” trial for early stage oropharyngeal, supraglottic and hypopharyngeal carcinoma: results of the benchmark case procedure

Author:

Stelmes J-JORCID,Vu E.,Grégoire V.,Simon C.,Clementel E.,Kazmierska J.,Grant W.,Ozsahin M.,Tomsej M.,Vieillevigne L.,Fortpied C.,Hurkmans E. C.,Branquinho A.,Andratschke N.,Zimmermann F.,Weber D.-C.

Abstract

Abstract Introduction The current phase III EORTC 1420 Best-of trial (NCT02984410) compares the swallowing function after transoral surgery versus intensity modulated radiotherapy (RT) in patients with early-stage carcinoma of the oropharynx, supraglottis and hypopharynx. We report the analysis of the Benchmark Case (BC) procedures before patient recruitment with special attention to dysphagia/aspiration related structures (DARS). Materials and methods Submitted RT volumes and plans from participating centers were analyzed and compared against the gold-standard expert delineations and dose distributions. Descriptive analysis of protocol deviations was conducted. Mean Sorensen-Dice similarity index (mDSI) and Hausdorff distance (mHD) were applied to evaluate the inter-observer variability (IOV). Results 65% (23/35) of the institutions needed more than one submission to achieve Quality assurance (RTQA) clearance. OAR volume delineations were the cause for rejection in 53% (40/76) of cases. IOV could be improved in 5 out of 12 OARs by more than 10 mm after resubmission (mHD). Despite this, final IOV for critical OARs in delineation remained significant among DARS by choosing an aleatory threshold of 0.7 (mDSI) and 15 mm (mHD). Conclusions This is to our knowledge the largest BC analysis among Head and neck RTQA programs performed in the framework of a prospective trial. Benchmarking identified non-common OARs and target delineations errors as the main source of deviations and IOV could be reduced in a significant number of cases after this process. Due to the substantial resources involved with benchmarking, future benchmark analyses should assess fully the impact on patients’ clinical outcome.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3