Strict bladder filling and rectal emptying during prostate SBRT: Does it make a dosimetric or clinical difference?

Author:

Byun David J.,Gorovets Daniel J.,Jacobs Lauren M.,Happersett Laura,Zhang Pengpeng,Pei Xin,Burleson Sarah,Zhang Zhigang,Hunt Margie,McBride Sean,Kollmeier Marisa A.,Zelefsky Michael J.

Abstract

Abstract Background To evaluate inter-fractional variations in bladder and rectum during prostate stereotactic body radiation therapy (SBRT) and determine dosimetric and clinical consequences. Methods Eighty-five patients with 510 computed tomography (CT) images were analyzed. Median prescription dose was 40 Gy in 5 fractions. Patients were instructed to maintain a full bladder and empty rectum prior to simulation and each treatment. A single reviewer delineated organs at risk (OARs) on the simulation (Sim-CT) and Cone Beam CTs (CBCT) for analyses. Results Bladder and rectum volume reductions were observed throughout the course of SBRT, with largest mean reductions of 86.9 mL (19.0%) for bladder and 6.4 mL (8.7%) for rectum noted at fraction #5 compared to Sim-CT (P < 0.01). Higher initial Sim-CT bladder volumes were predictive for greater reduction in absolute bladder volume during treatment (ρ = − 0.69; P < 0.01). Over the course of SBRT, there was a small but significant increase in bladder mean dose (+ 4.5 ± 12.8%; P < 0.01) but no significant change in the D2cc (+ 0.8 ± 4.0%; P = 0.28). The mean bladder trigone displacement was in the anterior direction (+ 4.02 ± 6.59 mm) with a corresponding decrease in mean trigone dose (− 3.6 ± 9.6%; P < 0.01) and D2cc (− 6.2 ± 15.6%; P < 0.01). There was a small but significant increase in mean rectal dose (+ 7.0 ± 12.9%, P < 0.01) but a decrease in rectal D2cc (− 2.2 ± 10.1%; P = 0.04). No significant correlations were found between relative bladder volume changes, bladder trigone displacements, or rectum volume changes with rates of genitourinary or rectal toxicities. Conclusions Despite smaller than expected bladder and rectal volumes at the time of treatment compared to the planning scans, dosimetric impact was minimal and not predictive of detrimental clinical outcomes. These results cast doubt on the need for excessively strict bladder filling and rectal emptying protocols in the context of image guided prostate SBRT and prospective studies are needed to determine its necessity.

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3