Dosimetric feasibility of moderately hypofractionated/dose escalated radiation therapy for localised prostate cancer with intensity-modulated proton beam therapy using simultaneous integrated boost (SIB-IMPT) and impact of hydrogel prostate-rectum spacer

Author:

Ahmad Khalil Dalia,Jazmati Danny,Geismar Dirk,Wulff Jörg,Bäumer Christian,Kramer Paul Heinz,Steinmeier Theresa,Schulze Schleitthoff Stefanie,Plaude Sandija,Bischoff Martin,Tschirdewahn Stephan,Hadaschik Boris,Timmermann Beate

Abstract

Abstract Purpose To examine the dosimetric feasibility of hypofractionated/dose escalated radiation therapy in patients with localized prostate carcinoma using simultaneous integrated boost intensity-modulated proton beam therapy (SIB-IMPT) in absence or presence of prostate-rectum spacer. Methods IMPT technique was implemented in 23 patients with intermediate- and high-risk prostate cancer treated at West German Proton Therapy Centre from March 2016 till June 2018, using SIB technique prescribing 60 GyRBE and 72 GyRBE in 30 fractions to PTV1 (prostate and seminal vesicle) and PTV2 boost (prostate and proximal seminal vesicle), respectively. In 15 patients, a transperineal injection of hydrogel was applied prior to radiotherapy to increase the distance between prostate and rectum. Planning and all treatments were performed with a 120 ml fluid-filled endorectal balloon customised daily for each patient. For each patient, 2 lateral IMPT beams were implemented taking a field-specific range uncertainty (RU) into account. Dose volume histograms (DVH) were analyzed for PTV2, PTV2 with range uncertainty margin (PTV2RU), rectum, bladder, right/left femoral heads, and penile bulb. For late rectal toxicities, the normal tissue complication probabilities (NTCP) were calculated using different biological models. A DVH- and NTCP-based dosimetric comparison was carried out between non-spacer and spacer groups. Results For the 23 patients, high-quality plans could be achieved for target volume and for other organs at risk (OARs). For PTV2, the V107% was 0% and the Dmax did not exceed 106.2% of the prescribed dose. The volume PTV2RU covered by 95% of the dose ranged from 96.16 to 99.95%. The conformality index for PTV2RU was 1.12 ± 0.057 and the homogeneity index (HI) was 1.04 ± 0.014. Rectum Dmax and rectal volume receiving 73–50 Gy could be further reduced for the spacer-group. Significant reductions in mean and median rectal NTCPs (stenosis/necrosis, late rectal bleeding ≥ 2, and late rectal toxicities ≥ 3) were predicted for the spacer group in comparison to the non-spacer group. Conclusion Hypofractionated/dose escalated radiotherapy with SIB-IMPT is dosimetrically feasible. Further reduction of the rectal volumes receiving high and medium dose levels (73–50 Gy) and rectal NTCP could be achieved through injection of spacers between rectum and prostate.

Funder

Universitätsklinikum Essen

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3