Uncovering high rates of unsafe injection equipment reuse in rural Cameroon: validation of a survey instrument that probes for specific misconceptions

Author:

Okwen Mbah P,Ngem Bedes Y,Alomba Fozao A,Capo Mireille V,Reid Savanna R,Ewang Ebong C

Abstract

Abstract Background Unsafe reuse of injection equipment in hospitals is an on-going threat to patient safety in many parts of Africa. The extent of this problem is difficult to measure. Standard WHO injection safety assessment protocols used in the 2003 national injection safety assessment in Cameroon are problematic because health workers often behave differently under the observation of visitors. The main objective of this study is to assess the extent of unsafe injection equipment reuse and potential for blood-borne virus transmission in Cameroon. This can be done by probing for misconceptions about injection safety that explain reuse without sterilization. These misconceptions concern useless precautions against cross-contamination, i.e. "indirect reuse" of injection equipment. To investigate whether a shortage of supply explains unsafe reuse, we compared our survey data against records of purchases. Methods All health workers at public hospitals in two health districts in the Northwest Province of Cameroon were interviewed about their own injection practices. Injection equipment supply purchase records documented for January to December 2009 were compared with self-reported rates of syringe reuse. The number of HIV, HBV and HCV infections that result from unsafe medical injections in these health districts is estimated from the frequency of unsafe reuse, the number of injections performed, the probability that reused injection equipment had just been used on an infected patient, the size of the susceptible population, and the transmission efficiency of each virus in an injection. Results Injection equipment reuse occurs commonly in the Northwest Province of Cameroon, practiced by 44% of health workers at public hospitals. Self-reported rates of syringe reuse only partly explained by records on injection equipment supplied to these hospitals, showing a shortage of syringes where syringes are reused. Injection safety interventions could prevent an estimated 14-336 HIV infections, 248-661 HBV infections and 7-114 HCV infections each year in these health districts. Conclusions Injection safety assessments that probe for indirect reuse may be more effective than observational assessments. The autodisable syringe may be an appropriate solution to injection safety problems in some hospitals in Cameroon. Advocacy for injection safety interventions should be a public health priority.

Publisher

Springer Science and Business Media LLC

Subject

Psychiatry and Mental health,Public Health, Environmental and Occupational Health,Medicine (miscellaneous)

Reference76 articles.

1. Apetrei C, Becker J, Metzger M, Gautam R, Engle J, Wales A, Eyong M, Sama M, Foley B, Drucker E, Marx P: Potential for HIV transmission through unsafe injections. AIDS. 2006, 20: 1074-1076. 10.1097/01.aids.0000222085.21540.8a.

2. Simonsen L, Kane A, Lloyd J, Zaffran M, Kane M: Unsafe injections in the developing world and transmission of bloodborne pathogens: a review. Bull World Health Organ. 1999, 77: 789-800.

3. Linegar A: Re-use of single-use disposable instrumentation. S Afr Med J. 2000, 90: 1097-1098.

4. UNICEF: Cameroon Statistics. 2008, [http://www.unicef.org/infobycountry/cameroon_statistics.html]

5. Dziekan G, Chisholm D, Johns B, Rovira J, Hutin Y: The cost-effectiveness of policies for the safe and appropriate use of injection in health care settings. Bull World Health Organ. 2003, 81: 277-285.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3