Author:
Pandey Manoj,Deo Surya VS,Maharajan R
Abstract
Abstract
Background
Preoperative lymphoscintigraphy is one of the three methods of evaluating sentinel nodes in patients with breast cancer; however, it has been reported to have a high false negative rate.
Case presentations
We report here two cases where the preoperative lymphoscintigraphy was found to be fallacious. A 44-year-old female with T2N0 breast cancer underwent preoperative lymphoscintigraphy with Tc99 sulfur colloid which failed to show any uptake in axilla or internal mammary chain. Intraoperative scintigraphy with blue dye and hand held gamma probe identified sentinel lymph node in axilla. Another patient with T2N0 lesion underwent preoperative lymphoscintigraphy which showed a sentinel lymph node in axilla and another in supraclevicular fossa. Intraoperative scintigraphy failed to show supraclevicular node however axillary node was correctly identified.
Conclusion
These two cases further strengthen the need to carry out triple test in identification of sentinel lymph node in patients with breast cancer. It also demonstrates the fallacies of preoperative lymphoscintigraphy.
Publisher
Springer Science and Business Media LLC
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献