Inverted internal limiting membrane-flap technique for large macular hole: a microperimetric study

Author:

Sborgia Giancarlo,Niro AlfredoORCID,Sborgia Alessandra,Albano Valeria,Tritto Tiziana,Sborgia Luigi,Pastore Valentina,Donghia Rossella,Giancipoli Ermete,Recchimurzo Nicola,Boscia Francesco,Alessio Giovanni

Abstract

Abstract Background Inverted Internal Limiting Membrane (ILM)-flap technique would seem to lead to higher closure rate and better visual acuity than traditional procedure with ILM peeling for the treatment of large macular hole (LMH). Visual acuity recovery does not reveal many other functional changes related to surgical approach. Our purpose was to evaluate macular function and morphology over a 1-year follow-up after inverted ILM-flap technique for LMH by using microperimetry in order to predict visual prognosis. Methods This study was a prospective unrandomized single-center study. 23 eyes of 22 patients with idiopathic LMH, with a minimum diameter ranging from 400 to 1000 μm, were included. All patients underwent vitrectomy with inverted ILM-flap technique and gas tamponade. We analyzed macular hole closure rate and functional outcomes including best-corrected visual acuity (BCVA), macular sensitivity (MS) at central 12° and central macular sensitivity (CMS) at central 4°, and fixation behavior as bivariate contour ellipse area (BCEA, degrees2) at 68%, 95%, and 99% of fixation points measured by microperimeter, over a follow-up of 12 months. Results The macular hole closure rate was 98%. The BCVA improved from 20/230 (Logmar, 1.06 ± 0.34) to 20/59 (logMar, 0.47 ± 0.45) at last follow-up (p < 0.001). Retinal sensitivity and BCEA significantly improved (MS, p = 0.001; CMS, p < 0.0001; BCEA: 68%, p < 0.01; 95%, p < 0.01; 99%, p = 0.001). Multiple stepwise regression analysis showed the final BCVA was significantly associated with macular hole size (β = 0.002, p = 0.03), preoperative MS (β = − 0.06, p = 0.001) and BCEA at 95% and 99% of fixation points (β = − 0.12, p = 0.01; β = 0.06, p = 0.01). Conclusions Inverted ILM-flap technique for LMH results in good morphologic and functional outcomes. Macular hole size and microperimetric parameters as preoperative MS and BCEA have a predictive role on post-surgical visual acuity.

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3