Completing the view – histologic insights from circular AAA specimen including 3D imaging

Author:

Menges Anna-Leonie,Nackenhorst Maja,Müller Johannes R.,Engl Marie-Luise,Hegenloh Renate,Pelisek Jaroslav,Geibelt Ellen,Hofmann Anja,Reeps Christian,Biro Gabor,Eckstein Hans-Henning,Zimmermann Alexander,Magee Derek,Falk Martin,Sachs Nadja,Busch AlbertORCID

Abstract

AbstractAbdominal aortic aneurysm (AAA) is a pathologic enlargement of the infrarenal aorta with an associated risk of rupture. However, the responsible mechanisms are only partially understood. Based on murine and human samples, a heterogeneous distribution of characteristic pathologic features across the aneurysm circumference is expected. Yet, complete histologic workup of the aneurysm sac is scarcely reported. Here, samples from five AAAs covering the complete circumference partially as aortic rings are investigated by histologic means (HE, EvG, immunohistochemistry) and a new method embedding the complete ring. Additionally, two different methods of serial histologic section alignment are applied to create a 3D view. The typical histopathologic features of AAA, elastic fiber degradation, matrix remodeling with collagen deposition, calcification, inflammatory cell infiltration and thrombus coverage were distributed without recognizable pattern across the aneurysm sac in all five patients. Analysis of digitally scanned entire aortic rings facilitates the visualization of these observations. Immunohistochemistry is feasible in such specimen, however, tricky due to tissue disintegration. 3D image stacks were created using open-source and non-generic software correcting for non-rigid warping between consecutive sections. Secondly, 3D image viewers allowed visualization of in-depth changes of the investigated pathologic hallmarks. In conclusion, this exploratory descriptive study demonstrates a heterogeneous histomorphology around the AAA circumference. Warranting an increased sample size, these results might need to be considered in future mechanistic research, especially in reference to intraluminal thrombus coverage. 3D histology of such circular specimen could be a valuable visualization tool for further analysis.

Funder

Universitätsklinikum Carl Gustav Carus Dresden an der Technischen Universität Dresden

Publisher

Springer Science and Business Media LLC

Subject

General Medicine,Histology,Pathology and Forensic Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3