Case report: When measured free T4 and free T3 may be misleading. Interference with free thyroid hormones measurements on Roche® and Siemens® platforms

Author:

Lewandowski Krzysztof C,Dąbrowska Katarzyna,Lewiński Andrzej

Abstract

Abstract A 59-year old female patient presented with apathy and 6 kg weight gain. Investigations revealed severe primary hypothyroidism (TSH>100 μIU/ml). L-thyroxine (L-T4) was started and titrated up to 75 μg, once daily, with clinical improvement. Other investigations revealed very high titres of anti-thyroid peroxidase (anti-TPO) and anti-thyroglobulin (anti-Tg) antibodies. After three months, there was a fall in TSH to 12.74 μIU/ml, however, with unexpectedly high free T4 (FT4) - 6.8 ng/ml and free T3 (FT3) - 6.7 pg/ml concentrations [reference range (rr): 0.8-1.9 ng/ml and 1.5-4.1 pg/ml (Siemens®), respectively]. At this stage L-T4 was stopped, and this was followed by a rapid increase in TSH (to 77.76 μIU/ml) and some decrease in FT4 and FT3, however FT4 concentration remained elevated (2.1 ng/ml). Following this, L-T4 was restarted. On admission to our Department, she was clinically euthyroid on L-T4, 88 μg, once daily. Investigations on Roche® platform confirmed mildly elevated TSH - 5.14 (rr: 0.27-4.2 μIU/ml) with high FT4 [4.59 (rr: 0.93-1.7 ng/ml)] and FT3 [4.98 (rr: 2.6-4.4 pg/ml)] concentrations. Other tests revealed hypoechogenic ultrasound pattern typical for Hashimoto thyroiditis. There was no discrepancy in calculated TSH value following TSH dilution (101% recovery). Concentrations of FT4 and FT3 were assessed on the day of discontinuation of L-T4 and after four days by the means of Abbott® Architect I 1000SR platform. These revealed FT4 and FT3 concentrations within the reference range [e.g., FT4 - 1.08 ng/ml (rr: 0.7-1.48)] vs 4.59 ng/ml (rr: 0.93-1.7, Roche®), FT3 - 3.70 pg/ml (rr: 1.71-3.71) vs 4.98 (rr: 2.6-4.4, Roche®)], confirming assay interference. Concentrations of ferritin and SHBG were normal. Conclusions Clinicians must be aware of possible assay interference, including the measurements of FT4 and FT3 in the differential diagnosis of abnormal results of thyroid function tests that do not fit the patient clinical presentation.

Publisher

Springer Science and Business Media LLC

Subject

Endocrine and Autonomic Systems,Endocrinology,Endocrinology, Diabetes and Metabolism

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3