Simultaneous and enantiospecific quantification of primaquine and carboxyprimaquine in human plasma using liquid chromatography-tandem mass spectrometry

Author:

Hanpithakpong Warunee,Day Nicholas P. J.,White Nicholas J.,Tarning JoelORCID

Abstract

Abstract Background The enantiomers of the 8-aminoquinoline anti-malarial primaquine have different pharmacological properties. Development of an analytical method for simultaneous quantification of the enantiomers of primaquine and its metabolite, carboxyprimaquine, will support clinical pharmacometric assessments. Methods A simple and sensitive method consisting of liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) was developed for simultaneous and enantiospecific determination of primaquine and its metabolite, carboxyprimaquine, in human plasma. Stable isotopes were used as internal standards to compensate for potential interference and matrix effects. Plasma samples (100 µL) were precipitated with 1% formic acid in acetonitrile followed by phospholipid removal solid phase extraction. Primaquine and carboxyprimaquine enantiomers were separated on a Chiralcel OD-3R (150 mm × 4.6 mm; I.D. 3 μm) column using a LC gradient mode. For separation of racemic primaquine and carboxyprimaquine, the LC method was modified and validated using a reverse phase column (Hypersil Gold 100 mm × 4.6 mm; I.D. 3 µm) and a mobile phase composed of 10 mM ammonium acetate buffer, pH 3.5 and acetonitrile in the isocratic mode. Method validation was performed according to regulatory guidelines. Results The calibration range was set to 0.571–260 ng/mL and 2.44–2,500 ng/mL for primaquine and carboxyprimaquine enantiomers, respectively, resulting in a correlation coefficient (r2) ≥ 0.0998 for all calibration curves. The intra- and inter-day assay precisions were < 10% and the accuracy was between 94.7 to 103% for all enantiomers of primaquine and carboxyprimaquine. The enantiospecific method was also modified and validated to quantify racemic primaquine and carboxyprimaquine, reducing the total run time from 30 to 8 min. The inter-, intra-day assay precision of the racemic quantification method was < 15%. The absolute recoveries of primaquine and carboxyprimaquine were between 70 and 80%. Stability was demonstrated for up to 2 years in − 80 °C. Both the enantiomeric and racemic LC–MS/MS methods were successfully implemented in pharmacokinetic studies in healthy volunteers. Conclusions Simple, sensitive and accurate LC–MS/MS methods for the quantification of enantiomeric and racemic primaquine and carboxyprimaquine in human plasma were validated successfully and implemented in clinical routine drug analysis.

Funder

Wellcome Trust

Publisher

Springer Science and Business Media LLC

Subject

Infectious Diseases,Parasitology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3