Author:
Zanotto Tobia,Mercer Thomas H.,van der Linden Marietta L.,Traynor Jamie P.,Koufaki Pelagia
Abstract
Abstract
Background
Physical frailty is a major health concern among people receiving haemodialysis (HD) for stage-5 chronic kidney disease (CKD-5). Wearable accelerometers are increasingly being recommended to objectively monitor activity levels in CKD-5 and recent research suggests they may also represent an innovative strategy to evaluate physical frailty in vulnerable populations. However, no study has yet explored whether wearable accelerometers may be utilised to assess frailty in the context of CKD-5-HD. Therefore, we aimed to examine the diagnostic performance of a research-grade wearable accelerometer in evaluating physical frailty in people receiving HD.
Methods
Fifty-nine people receiving maintenance HD [age = 62.3 years (SD = 14.9), 40.7% female] participated in this cross-sectional study. Participants wore a uniaxial accelerometer (ActivPAL) for seven consecutive days and the following measures were recorded: total number of daily steps and sit-to-stand transitions, number of daily steps walked with cadence < 60 steps/min, 60–79 steps/min, 80–99 steps/min, 100–119 steps/min, and ≥ 120 steps/min. The Fried phenotype was used to evaluate physical frailty. Receiver operating characteristics (ROC) analyses were performed to examine the diagnostic accuracy of the accelerometer-derived measures in detecting physical frailty status.
Results
Participants classified as frail (n = 22, 37.3%) had a lower number of daily steps (2363 ± 1525 vs 3585 ± 1765, p = 0.009), daily sit-to-stand transitions (31.8 ± 10.3 vs 40.6 ± 12.1, p = 0.006), and lower number of steps walked with cadence of 100–119 steps/min (336 ± 486 vs 983 ± 797, p < 0.001) compared to their non-frail counterparts. In ROC analysis, the number of daily steps walked with cadence ≥ 100 steps/min exhibited the highest diagnostic performance (AUC = 0.80, 95% CI: 0.68–0.92, p < 0.001, cut-off ≤ 288 steps, sensitivity = 73%, specificity = 76%, PPV = 0.64, NPV = 0.82, accuracy = 75%) in detecting physical frailty.
Conclusions
This study provided initial evidence that a wearable accelerometer may be a useful tool in evaluating physical frailty in people receiving HD. While the total number of daily steps and sit-to-stand transitions could significantly discriminate frailty status, the number of daily steps walked with cadences reflecting moderate to vigorous intensity of walking may be more useful in monitoring physical frailty in people receiving HD.
Funder
British Kidney Patient Association - British Renal Society
Publisher
Springer Science and Business Media LLC
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献