Substitution of citrate with tissue plasminogen activator (rt-PA) for catheter lock does not improve patency of tunnelled haemodialysis catheters in a randomised trial

Author:

Richtrova PavlinaORCID,Mares Jan,Kielberger Lukas,Klaboch Jan,Eiselt Jaromir,Reischig Tomas

Abstract

Abstract Backround The study aim was to establish if substitution of citrate with rt-PA for catheter lock once weekly can reduce the incidence of catheter-related blood stream infections (CR-BSI) or improve patency of tunneled haemodialysis catheters. Methods All incident patients undergoing insertion of a tunneled haemodialysis catheter were screened and included except those suffering infection or using oral anticoagulation. Study participants were randomized into two arms according to the solution applied as catheter lock: receiving either trisodium citrate (Citra-LockTM 4%) only or rt-PA (Actilyse® 1 mg/ml) on the middle session each week with citrate used on the first and third sessions. The incidence of CR-BSI (confirmed by positive blood culture), catheter non-function (complete obstruction), and malfunction (blood flow < 250 ml/min) was recorded. Statistical significance was tested with ANOVA, post hoc analysis was performed by means of multiple linear regression. Results Totally, 18 patients were included and followed during 655 haemodialysis sessions. No episode of CR-BSI was detected while 6 catheter non-functions (0.9% sessions) and 101 malfunctions (15.4% sessions) were recorded. The incidence of both events was equal between the study arms: 4 non-functions and 55 malfunctions in the rt-PA arm and 2 non-functions and 46 malfunctions in the citrate arm (p = 0.47 and p = 0.24, respectively). Additionally, the mean blood flow achieved did not differ significantly between the arms: 326 ± 1,8 and 326 ± 1,9 ml/min (p = 0.95) in rt-PA and citrate arms, respectively. Post hoc analysis identified time elapsed since previous session (β = 0.12, p = 0.005) and malfunction on previous session (β = 0.25, p < 0.001) as significant factors affecting the occurrence of malfunction. By contrast, the study arm, rt-PA application on previous session, and catheter vintage did not enter the model. Conclusion Substitution of citrate with rt-PA for catheter lock does not reduce the incidence of catheter malfunction neither does it affect the blood flow achieved during haemodialysis. Catheter patency is related rather to the time interval between sessions and to previous malfunction (thus probably reflecting undefined individual factors). The incidence of CR-BSI within pre-selected haemodialysis population is sporadic (less than 1 per 4.3 patient years in our sample). Trial registration Australian New Zealand Clinical Trials Registry, ACTRN12612000152820. Retrospectively registered 03/02/2012.

Funder

Ministry of Education, Youth and Sports of the Czech Republic

Ministry of Education, Youth, and Sports of the Czech Republic

Ministry of Education, Youth and Sports od the Czech Republic

Publisher

Springer Science and Business Media LLC

Subject

Nephrology

Reference30 articles.

1. Vascular Access Work Group. Clinical Practice guidelines for vascular access. Am J Kidney Dis. 2006;48(Suppl 1):S176–247.

2. Lee T. Fistula first initiative: historical impact on vascular access practice patterns and influence on future vascular access care. Cardiovasc Eng Technol. 2017;8(3):244–54.

3. National Kidney Foundation. KDOQI Clinical Practice Guidelines and Clinical Practice Recommendations for 2006 Updates: Hemodialysis Adequacy, Peritoneal Dialysis Adequacy and Vascular Access. Am J Kidney Dis. 2006;48(suppl 1):S1–S322.

4. Ravani P, Palmer SC, Oliver MJ, et al. Associations between hemodialysis access type and clinical outcomes: a systematic review. J Am Soc Nephrol. 2013;24:465–73.

5. Ravani P, Gillespie BW, Quinn RR, et al. Temporal risk profile for infec- tious and noninfectious complications of hemodialysis access. J Am Soc Nephrol. 2013;24:1668–77.