Abstract
Abstract
Background
The separate and combined effects of intradialytic exercise training (IET) and cold dialysis (CD) on patient thermoregulation remain unknown. This study assessed the thermoregulatory responses of hemodialysis patients under four different hemodialysis protocols: a) one typical dialysis (TD) protocol (dialysate temperature at 37 °C), b) one cold dialysis (CD) protocol (dialysate temperature at 35 °C), c) one typical dialysis protocol which included a single exercise bout (TD + E), d) one cold dialysis protocol which included a single exercise bout (CD + E).
Methods
Ten hemodialysis patients (57.2 ± 14.9 years) participated in this randomized, cross-over study. Core and skin temperatures were measured using an ingestible telemetric pill and by four wireless iButtons attached on the skin, respectively. Body heat storage (S) calculated using the thermometric method proposed by Burton.
Results
The TD and TD + E protocols were associated with increased S leading to moderate effect size increases in core body temperature (as high as 0.4 °C). The low temperature of the dialysate during the CD and the CD + E protocols prevented the rise in S and core temperature (p > 0.05), even during the period that IET took place.
Conclusions
TD and IET are accompanied by a moderate level of hyperthermia, which can be offset by CD. We recommended that CD or with IET can prevent the excessive rise of S.
Trial registration
Clinical Trial Registry number: NCT03905551 (clinicaltrials.gov), DOR: 05/04/2019,
Funder
H2020 Marie Skłodowska-Curie Actions
Publisher
Springer Science and Business Media LLC
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献