A comparison of the utility of the urine dipstick and urine protein-to-creatinine ratio for predicting microalbuminuria in patients with non-diabetic lifestyle-related diseases -a comparison with diabetes

Author:

Ogi Makoto,Seto Takuya,Wakabayashi Yoshinori

Abstract

Abstract Background The utility of dipstick proteinuria for predicting microalbuminuria in non-diabetic lifestyle-related diseases compared with the urine protein-to-creatinine ratio (uPCR) and the effect of dipstick proteinuria on the cut-off value (CO) and accuracy of uPCR are unclear. Methods The subjects included Japanese patients ≥ 18 years old with lifestyle-related diseases who had an estimated glomerular filtration rate of ≥ 15 ml/min/1.73 m2 and uPCR of < 0.5 g/gCr at initiation. Urine dipstick, uPCR and urine albumin-to-creatinine ratio (uACR) were measured three times per case. Microalbuminuria was defined as uACR of 30–299 mg/gCr for at least 2 of 3 measurements. Youden’s Index was used as the optimal CO. Factors associated with microalbuminuria were analyzed using a logistic regression model. Results In 313 non-diabetic cases (median 70.8 years old), 3 dipstick proteinuria measurements were independently useful for detecting microalbuminuria, and the CO was set when a trace finding was obtained at least 1 of 3 times (sensitivity 0.56, specificity 0.80, positive predictive value [PPV] 0.73, negative predictive value [NPV] 0.65). A single uPCR measurement was more useful than 3 dipstick measurements, and was useful for detecting microalbuminuria even in cases with three consecutive negative proteinuria findings, indicating that the CO of the second uPCR with G1-3a (n = 136) was 0.06 g/gCr (sensitivity 0.76, specificity 0.84. PPV 0.68, NPV 0.89), while that with G3-b4 (n = 59) was 0.10 g/gCr (sensitivity 0.56, specificity 0.91. PPV 0.83, NPV 0.71). The sum of 3 uPCRs was useful for detecting microalbuminuria in cases with G1-3a (sensitivity 0.67, specificity 0.94, PPV 0.82, NPV 0.86) and G3b-4 (sensitivity 0.78, specificity 0.94, PPV 0.91 NPV 0.83), with both COs being 0.23 g/gCr. These COs of microalbuminuria did not change when trace or more proteinuria was included, although the sensitivity increased. A high uPCR and low urine specific gravity or creatinine level were independent factors for uACR ≥ 30 mg/gCr in cases with negative proteinuria, although the uPCR was a major predictive factor of a uACR ≥ 30 mg/gCr. Conclusions The uPCR (preferably determined using early-morning urine), including in dipstick-negative proteinuria cases with non-diabetic lifestyle-related diseases, can aid in the early detection of microalbuminuria. Trial registration Retrospectively registered.

Publisher

Springer Science and Business Media LLC

Subject

Nephrology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3