Comparison of two ferritin assay platforms to assess their level of agreement in measuring serum and plasma ferritin levels in patients with chronic kidney disease

Author:

Majoni Sandawana William,Nelson Jane,Graham Jessica,Abeyaratne Asanga,Fernandes David Kiran,Cherian Sajiv,Rathnayake Geetha,Ashford Jenna,Hocking Lynn,Cain Heather,McFarlane Robert,Lawton Paul Damian,Barzi Federica,Taylor Sean,Cass Alan

Abstract

Abstract Background Ferritin levels are used to make decisions on therapy of iron deficiency in patients with chronic kidney disease (CKD). Hyperferritinaemia, common among patients with CKD from the Northern Territory (NT) of Australia, makes use of ferritin levels as per clinical guidelines challenging. No gold standard assay exists for measuring ferritin levels. Significant variability between results from different assays creates challenges for clinical decision-making regarding iron therapy. In the NT, different laboratories use different methods. In 2018, Territory Pathology changed the assay from Abbott ARCHITECT i1000 (AA) to Ortho-Clinical Diagnostics Vitros 7600 (OCD). This was during the planning of the INtravenous iron polymaltose for First Nations Australian patients with high FERRitin levels on haemodialysis (INFERR) clinical trial. The trial design was based on AA assay ferritin levels. We compared the two assays’ level of agreement in measuring ferritin levels in CKD patients. Methods Samples from INFERR clinical trial participants were analysed. Other samples from patients whose testing were completed the same day on OCD analyzers and run within 24 h on AA analyzers were added to ensure wide range of ferritin levels, adding statistical strength to the comparison. Ferritin levels from both assays were compared using Pearson’s correlation, Bland–Altman, Deming and Passing-Bablok regression analyses. Differences between sample types, plasma and serum were assessed. Results Sixty-eight and 111 (179) samples from different patients from Central Australia and Top End of Australia, respectively, were analyzed separately and in combination. The ferritin levels ranged from 3.1 µg/L to 3354 µg/L and 3 µg/L to 2170 µg/L for AA and OCD assays respectively. Using Bland–Altman, Deming and Passing-Bablok regression methods for comparison, ferritin results were consistently 36% to 44% higher with AA than OCD assays. The bias was up to 49%. AA ferritin results were the same in serum and plasma. However, OCD ferritin results were 5% higher in serum than plasma. Conclusions When making clinical decisions, using ferritin results from the same assay in patients with CKD is critical. If the assay is changed, it is essential to assess agreement between results from the new and old assays. Further studies to harmonize ferritin assays are required.

Publisher

Springer Science and Business Media LLC

Subject

Nephrology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3