Electrophysiological studies versus high-resolution nerve ultrasound in diagnosis of Guillain–Barré syndrome

Author:

Abou Hagar Ahmed,Negm Mohamed,Elshamly Samer,Shehab Osama,Mosallam Walid,Abd El-Razek Reda

Abstract

Abstract Background Guillain–Barré syndrome (GBS) is polyneuropathy characterized by inflammation and immune-mediated processes that is classified into many subtypes based on electrophysiological and pathological criteria. The diagnosis of GBS can be confirmed using electrophysiological studies. However, electrophysiological studies may be normal when carried out early within 1 week in the course of the disease (Berciano et al. in J Neurol 264:221–236, 2017). One of the most useful imaging modalities for peripheral nerve diseases is ultrasonography (US). Nerve US in combination with electrophysiological studies provides an appropriate method in evaluating diseased peripheral nerves. This study aimed to enhance the reliability of early GBS diagnosis by correlating the findings of electrophysiological studies and nerve ultrasound. The nerve conduction studies (NCSs) in 37 GBS patients and 37 controls combined with cross-sectional area (CSA) assessment with US within the first 3 days of onset of symptoms and on day 14 after disease onset were evaluated. Results At presentation, patients and controls did not differ significantly in NCS parameters (p ≥ 0.05) except for a significantly longer F-wave minimum latency in the median, ulnar, and tibial nerves in patients (p < 0.001). While on day 14 all NCS parameters differed significantly in patients in comparison to controls (p < 0.001) with exception of the sural nerve parameters (p ≥ 0.05). Except for the sural nerve (p ≥ 0.05), all the examined nerves' CSAs were considerably higher in patients at presentation and on day 14 in comparison to the controls (p < 0.001). The subtypes of Guillain–Barré syndrome either demyelinating, axonal or mixed axonal and demyelinating did not significantly differ regarding the CSAs of all the examined nerves either at presentation or on day 14 (p > 0.05). Conclusion Electrophysiological results in GBS are crucial in diagnosing the disease and understanding its pathophysiology, but serial NCSs are required. Ultrasound shows structural aspects of the nerve, so ultrasonography is a reliable tool which can be used in diagnosis and follow-up of early GBS. As a result, combining the two investigations has a complementary effect in the diagnosis and prognosis of GBS.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3