Comparison of the accuracy of bracket positioning between direct and digital indirect bonding techniques in the maxillary arch: a three-dimensional study

Author:

Aboujaoude RamiORCID,Kmeid Roland,Gebrael Carine,Amm Elie

Abstract

Abstract Background/objectives When the indirect bonding technique was developed in 1972 by Silverman and Cohen, many authors wondered whether this technique would improve bracket positioning accuracy compared to the direct bonding technique. Studies have found little to no difference between them regarding positioning accuracy. Recently, technological advances have improved the indirect method by allowing the user to position the brackets virtually using software applications such as OrthoAnalyzer™. To the best of our knowledge, no studies have compared direct positioning to this new digital indirect technique. Thus, the aim of this study was to compare the accuracy of placement between the two techniques in the maxillary arch using two different bracket types: conventional twin brackets and self-ligating brackets. A secondary objective was to evaluate whether bracket type affected positioning accuracy. Methods A maxillary arch of a patient was scanned by digital impression. Forty resin duplicates of this model were printed and then mounted on a mannequin head, on which 20 practitioners performed direct bonding using the aforementioned brackets. Later on, they performed a virtual indirect bonding of the same case virtually, with the digital impression superimposed to the patient’s CBCT (cone-beam computed tomography). Afterwards, the direct bonded models were unmounted, scanned, and then superimposed to the indirect models. Differences in height, angulation and mesio-distal position of the brackets were evaluated. Results Regarding height, the differences between direct and indirect methods were not significant. Height difference was significantly greater for self-ligating brackets compared to conventional brackets. Regarding mesio-distal positioning, significant differences were noted for teeth 13 and 15 with self-ligating brackets (p-value = 0.019 and p-value = 0.043, respectively). The deviation was also greater for these brackets. Regarding angulation, the difference was significant on tooth 12 when using conventional brackets (p-value = 0.04) and on 12 and 22 when using self-ligating brackets (p-value = 0.09). Conclusion/implications There were no major significant differences between direct and indirect bonding. Differences were significant only on the laterals for of angulation, and on teeth 13 and 15 for mesio-distal centering. The bracket type seems to influence positioning accuracy, since self-ligating brackets had a larger deviation range than conventional brackets.

Publisher

Springer Science and Business Media LLC

Subject

Orthodontics

Reference33 articles.

1. Forshaw RJ. Orthodontics in antiquity: myth or reality. Br Dent J. 2016;221(3):137–40.

2. Philippe J. L’orthodontie d’Alexis Schange en 1841. Orthod Fr. 2017;88(3):213–7.

3. Proffit WR, Fields HW Jr., Sarver DM. Contemporary orthodontics. Elsevier; 2006.

4. Andrews LF. The straight-wire appliance. Explained and compared. J Clin Orthod. 1976;10(3):174–95.

5. Meyer M, Nelson G. Preadjusted edgewise appliances: theory and practice. Am J Orthod. 1978;73(5):485–98.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3