Abstract Background A non-invasive method has recently been introduced to remove osseo-integrated palatal implants by using the implantation ratchet which is designed to screw in or unscrew the implants. Although a proof of concept has been published, the torque involved to successfully explant have not been investigated so far. The aim of this study was to assess the removal torque required to explant osseo-integrated and orthodontically utilized palatal implants, and to identify potentially influencing variables. Materials and method Thirty-one consecutive patients (15 females, 16 males; mean age 24.1 ±7.4 years) with fully osseo-integrated and previously orthodontically loaded palatal implants (Orthosystem®: diameter 4.1mm/length 4.2mm/sandblasted with large grits (SLA) surface) were randomly assigned to either clockwise or counter-clockwise non-invasive explantation. The respective explantation tool with an electric torque control was placed on the abutment connection of the implant and secured by an occlusal screw. The primary outcome studied was maximal removal torque (MRT) needed to detach the implant from its socket which was recorded individually together with other potentially influencing secondary outcomes (gender, age, orthodontic loading time, use of local anaesthetics). Student’s t-test was used to contrast MRT difference for the gender, type of suprastructure, use of local anaesthetics, and rotational direction. Spearman correlations was used to investigate associations between MRT and patient’s age or duration loading time. Results Average MRT (148.6 ± 63.2N/cm) using ratchet as a non-invasive removal method of palatal implant was considered safe. The triangular head fractured of palatal implant at a torque level of 300.1 Ncm. Significantly higher explantation were recorded for male patients compared to female patients (182.0 ± 63.0 Ncm vs 112.8 ± 40.8 Ncm; P=0.001). On the other side, the mean removal torque for palatal removal in clockwise direction was non-significantly different (158.3 ± 58.6 Ncm) compared to counter-clockwise direction (139.4 ± 67.9 Ncm). Neither patient’s age (p=0.324) nor loading time (p=0.214) were significantly correlated with removal torque values. Conclusions Pertinent literature on this subject is practically non-existent, as orthodontics is presumably the only discipline where implant removal represents a treatment success. Mean MRT for successful palatal implant removal was 148.6±63.2Ncm, but a large spectrum was observed (minimum 31.5Ncm, maximum 272.8Ncm). This obvious heterogeneity underlines the importance to investigate possible influencing factors. The safe and simple non-invasive method for palatal implant removal necessitates moderate, but not high torque MRTs, independently of the torque direction. The necessary MRT seems clearly influenced by gender, but less so by patient’s age or loading time.

Publisher

Springer Science and Business Media LLC

Subject

Orthodontics

Reference25 articles.

1. Anitua E, Murias-Freijo A, Pinas L, Tejero R, Prado R, Orive G. Nontraumatic implant explantation: a biomechanical and biological analysis in Sheep Tibia. J Oral Implantol. 2016;42(1):3–11. https://doi.org/10.1563/aaid-joi-D-14-00193.

2. Cha JY, Takano-Yamamoto T, Hwang CJ. The effect of miniscrew taper morphology on insertion and removal torque in dogs. Int J Oral Maxillofac Implants. 2010;25(4):777–83.

3. Chen YJ, Chen YH, Lin LD, Yao CC. Removal torque of miniscrews used for orthodontic anchorage-a preliminary report. Int J Oral Maxillofac Implants. 2006;21(2):283–9.

4. Costa A, Raffainl M, Melsen B. Miniscrews as orthodontic anchorage: a preliminary report. Int J Adult Orthodon Orthognath Surg. 1998;13:201–9.

5. Fäh R, Schätzle M. Complications and adverse patient reactions associated with the surgical insertion and removal of palatal implants: a retrospective study. Clin Oral Implants Res. 2014;25:653–8.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Integrating skeletal anchorage into fixed and aligner biomechanics;Journal of the World Federation of Orthodontists;2022-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3