Abstract
Abstract
Introduction
This study aims to investigate the biomechanical effects of anchorage reinforcement using clear aligners (CAs) with microimplants during molar distalization. And also explores potential clinical strategies for enhancing anchorage in the sequential distalization process.
Methods
Finite element models were established to simulate the CAs, microimplants, upper dentition, periodontal ligament (PDL), and alveolar bone. In group set I, the 2nd molars underwent a distal movement of 0.25 mm in group set II, the 1st molars were distalized by 0.25 mm after the 2nd molars had been placed to a target position. Each group set consisted of three models: Model A served as the control model, Model B simulated the use of microimplants attached to the aligner through precision cuts, and Model C simulated the use of microimplants attached by buttons. Models B and C were subjected to a series of traction forces. We analyzed the effective contribution ratios of molar distalization, PDL hydrostatic stress, and von Mises stress of alveolar bone.
Results
The distalization of the 2nd molars accounted for a mere 52.86% of the 0.25-mm step distance without any reinforcement of anchorage. The remaining percentage was attributed to the mesial movement of anchorage teeth and other undesired movements. Models B and C exhibited an increased effective contribution ratio of molar distalization and a decreased loss of anchorage. However, there was a slight increase in the undesired movement of molar tipping and rotation. In group set II, the 2nd molar displayed a phenomenon of mesial relapse due to the reciprocal force produced by the 1st molar distalization. Moreover, the efficacy of molar distalization in terms of contribution ratio was found to be positively correlated with the magnitude of force applied. In cases where stronger anchorage reinforcement is required, precision cuts is the superior method.
Conclusions
The utilization of microimplants in conjunction with CAs can facilitate the effective contribution ratio of molar distalization. However, it is important to note that complete elimination of anchorage loss is not achievable. To mitigate undesired movement, careful planning of anchorage preparation and overcorrection is recommended.
Funder
The National Natural Science Foundation of China
The CSA Clinical Research Fund
The National Clinical Research Center for Oral Diseases
Key Research and Development Program of Shaanxi Province
New Technologies and New Business of School of Stomatology, Air Force Medical University Fund
College Science and Technology Innovation Plan of Shanxi Education Department
Publisher
Springer Science and Business Media LLC
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献