TIP, TORQUE & ROTATIONS: How accurately do digital superimposition software packages quantify tooth movement?

Author:

Adel Samar M.ORCID,Vaid Nikhilesh R.,El-Harouni Nadia,Kassem Hassan,Zaher Abbas R.

Abstract

Abstract Background To investigate the accuracy of three different 3D digital model registration software for tip, torque and rotation measurements, with reference to a 3D digital virtual setup. Twenty maxillary and mandibular pre-treatment scans of patients undergoing clear aligner therapy were used. Digital setups were generated from pre-treatment scans using a tooth movement software. Both the pretreatment digital scans (T1) and digital setups (T2) were converted to STL files to be exported to the 3 studied software that employed: (1) Semiautomatic best fit registration (S-BF), (2) Interactive surface-based registration (I-SB), and (3) Automatic best fit registration (A-BF) respectively. Changes in tip, torque and rotation were calculated for all the registered pairs. Results The change in tooth position was compared between the calculated tooth movement using each of the registration software packages versus the actual generated tooth movement from the digital setups. Continuous data was expressed as mean and standard deviation. Intra Class Correlation Coefficient for agreement between digital simulation and each software was used. Intra and Inter-examiner reliabilities were also assessed using Intra Class Correlation Coefficient. Significance of the obtained results was expressed at p ≤ 0.01. Semiautomatic best fit registration software showed excellent agreement (> 0.90) for all tooth movements, except for good agreement for torque (0.808). Interactive surface-based registration software showed moderate agreement for all measurements (0.50 and < 0.75), except for good agreement for rotation (0.783). Automatic best fit registration software demonstrated excellent agreement (> 0.90) for rotation, good agreement for tip (0.890) and moderate agreement for torque (0.740). Conclusions Overall, semiautomatic best fit registration software consistently showed excellent agreement in superimpositions compared to other software types. Automatic best fit registration software consistently demonstrated better agreement for mandibular superimpositions, compared to others. Accuracy of digital model superimpositions for tooth movements studied in superimposition studies, can be attributed to the algorithm employed for quantification.

Publisher

Springer Science and Business Media LLC

Subject

Orthodontics

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3