A screw-type pacemaker lead implanted in the right atrium perforated the ascending aorta

Author:

Nakajima TomohiroORCID,Iba Yutaka,Shibata Tsuyoshi,Osamura Ayumu,Kamiyama Naoyuki,Nishikawa Ryo,Nakazawa Junji,Kawaharada Nobuyoshi

Abstract

Abstract Background Perforation by pacemaker leads, although rare, is a complication reported since the introduction of pacemaker therapy. Although historically reported frequencies were as high as 5%, recent reports have cited frequencies ranging from 1 to 2%. We report a case where a screw-type atrial lead slightly penetrated the right atrial wall, causing chronic abrasion of the ascending aorta, resulting in shock. Case presentation A 54-year-old male presented with dilated cardiomyopathy diagnosed at 40 years of age when he developed decompensated heart failure. Despite ongoing treatment, his heart failure worsened, leading to hospitalization at the age of 54. During his hospital stay, he experienced cardiac arrest that required cardiopulmonary resuscitation, followed by a return of spontaneous circulation. He was subsequently transferred to our institution after initiation of venoarterial extracorporeal membrane oxygenation (VA-ECMO) and an intra-aortic balloon pump (IABP). Echocardiography revealed an ejection fraction of 25%, left ventricular end-diastolic diameter of 60 mm, and severe mitral regurgitation (MR). Transcatheter mitral valve repair was performed to treat severe MR, followed by implantation of a cardiac resynchronization therapy defibrillator (CRT-D). Three months later, the patient was brought to our emergency department by ambulance because of hypotension. Contrast-enhanced computed tomography revealed pericardial effusion causing cardiac tamponade, necessitating emergency pericardial decompression via left fourth intercostal mini-thoracotomy and drain placement. Upon transfer to the intensive care unit, 1200 mL of blood was drained from the chest tube, prompting a return to the operating room for a median sternotomy. It was discovered that the pacemaker lead on the left side of the right atrium had slowly eroded into the aorta, leading to perforation. The ascending aorta was repaired and hemostasis was achieved; the patient recovered uneventfully and was discharged on postoperative day 18. Conclusions The pacemaker lead perforated the right atrium; chronic abrasion of the lead against the ascending aorta resulted in bleeding from the ascending aorta 3 months later.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3