Abstract
Abstract
Background
Most of TAVR centers evaluate the calcium score in contrast-enhanced (ce) CT. We compared in this study between different methodologies to measure calcium score. We studied also the difference between patients with low-gradient (LG) and high-gradient (HG) severe aortic stenosis (AS) as regard the burden of aortic valve calcium (AVC).
Results
We measured the calcium volume and score using Agatston methodology in non-contrast (nc) CT and with modified and fixed 850 Hounsfield unit (HU) thresholds in ce CT. The calcium score and volume in ceCT using even with modified thresholds is significantly lower than the assessed score and volume in ncCT. The median (IQR) of calcium score in nc CT and in cc CT were 1288 AU (750–1815) versus 947 HU (384–2202). The median (IQR) of calcium volume in nc CT and in cc CT with modified thresholds were 701 mm3 (239–1632) versus 197 mm3 (139–532). Agatston score and calcium volume were lower in patients with LG AS than HG AS; 2069 AU (899–2477) versus 928AU (572–1284) and 1537 mm3 (644–1860) versus 286 mm3 (160–700), respectively. Only 20% of patients with LGAS had Agatston score higher than the previously supposed AVC score threshold for the diagnosis of severe AS (> 2000AU in men and > 1200 in women).
Conclusions
The diagnosis of severe LGAS should not depend on a single parameter as calcium score. In these patients, calcium score should be measured in nc CT and not in ce CT.