Fatal pulmonary embolism following injectable gluteal filler usage: a case report

Author:

Shaheen SamehORCID,Al-Habbaa Ahmed,Riad Mohamed Saeid,Mandour Ahmed Saied,Elzeny Mahmoud Ali,Alnady Khaled

Abstract

Abstract Background Despite the fact that injectable filler usage in the gluteal region has not been recommended in formal medical institutions, illegal procedures are performed in many clinics and beauty centers across Egypt. This case report illustrates the illegal practice culminating in a fatal complication. Case presentation A 26-year-old female with no relevant medical history presented to the ER with acute onset shortness of breath. The complaint started 16 h before, with a rapidly progressive course, shortly after undergoing a gluteal filler injection at a center in Cairo. At ER, the patient was severely distressed, yet fully conscious and oriented. She was shocked (BP 70/40 mmHg), tachycardic (130 BPM), and tachypneic (30/min) with normal temperature. She had congested pulsating neck veins with positive Kussmaul sign. Chest auscultation revealed normal vesicular breathing with equal air entry and no adventitious sounds. Her O2 saturation was 60% on room air that improved to 85% on O2 mask. ECG showed sinus tachycardia. Echocardiography showed dilated right side, D-shaped septum with systolic flattening, dilated IVC, mild tricuspid regurgitation and estimated RV systolic pressure 53 mmHg. Her ABG showed compensated metabolic acidosis with elevated lactate level. At the ICU, CVP was 18 mmHg. Saline infusion was continued along with noradrenaline infusion initiation. A provisional diagnosis of high-risk pulmonary embolism was made, though CT pulmonary angiography was not available. Accordingly, thrombolytic therapy was initiated with alteplase (100 mg) over 2 h. Also, a dose of pulse steroids (methylprednisolone 200 mg) was given. Chest X-ray showed bilateral heterogenous opacity and ABG showed deteriorating hypoxia and combined metabolic and respiratory acidosis. The patient was intubated upon deterioration of conscious level and was put on mechanical ventilation. Her ET tube showed frequent blood-tinged secretions. Echocardiography showed more right-side dilatation that was consistent with deterioration of clinical status. Three hours after admission the patient developed cardiac arrest and died 2 h later. Conclusions This case report highlights the dangers associated with injectable filler usage in the gluteal region. Physicians and patients should be aware of the possible complications and how to avoid it.

Publisher

Springer Science and Business Media LLC

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3