Author:
Yu Hualiang,Lu Yongliang,Xiao Yi,Guo Jiaxiang,Yin Xiaotao,Yang Yu,Wang Hongwei,Gao Jiangping
Abstract
Abstract
Background
To investigate the surgical methods and clinical results of robot-assisted laparoscopic antegrade inguinal lymphadenectomy.
Methods
A retrospective study was performed on clinical data from 19 patients with penile cancer admitted from March 2013 to October 2017. Among them, nine patients underwent robot-assisted laparoscopic antegrade inguinal lymphadenectomy (robot-assisted group) and 10 patients underwent open inguinal lymphadenectomy (open group). In the robot-assisted group, preoperative preparation, patient position, robot placement, design of operating channel and establishment of operating space are described. Key surgical procedures and techniques are also summarized. In addition, the number of lymph nodes removed, postoperative complications and follow-up in both groups were statistically analyzed.
Results
For the 9 patients in the robot-assisted group, surgery was successfully accomplished at 17 sides without intraoperative conversion to open surgery. The surgery time for each side was 45~90 min using laparoscope with an average of 68.5 ± 13.69 min/side. The intraoperative blood loss was estimated to be < 10 ml/side, and the number of removed lymph nodes was not significantly different from that of the open group (12 ± 4.2/side vs.11 ± 5.8/side, P = 0.84). There were no postoperative complications such as skin necrosis, delayed wound healing and cellulitis in the robot-assisted group. Skin-related complications occurred in 9 (45%) of the 20 sides in the open group. During a median follow-up of 25 months in robot-assisted group and 52.5 mouths in open group, was not significantly different there were no statistical differences in recurrence-free survival between the groups (75% vs 60%, p = 0.536).
Conclusion
Robot-assisted laparoscopic antegrade inguinal lymphadenectomy achieved the desired surgical outcomes with fewer intraoperative and postoperative complications. The robotic arms of the surgical system were placed between the lower limbs of each patient. There was no need to re-position the robotic arms during bilateral inguinal lymphadenectomy. This simplified the procedure and reduced the use of trocars. If necessary, pelvic lymphadenectomy could be performed simultaneously using the original trocar position.
Publisher
Springer Science and Business Media LLC
Subject
Urology,Reproductive Medicine,General Medicine
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献