Failure in Double-J stent inserting in laparoscopic pyeloplasty of ureteropelvic junction obstruction: the clinical features and outcomes

Author:

Wang XinyuORCID,Li JiayiORCID,Fan Songqiao,Li Zonghan,Yang Zhenzhen,Liu Pei,Song Hongcheng,Zhang Weiping

Abstract

Abstract Background Double-J (DJ) stent placement is an important procedure during laparoscopic pyeloplasty (LP). Failing to insert the DJ stent may indicate the patient was also complicated with uretero-vesical junction obstruction (UVJO), and surgeons have to change to another alternative drainage method. In the present study, we analyzed the risk factors of failure of DJ stent placement during the LP and reviewed the clinical outcomes of these challenging pyeloplasties. Methods We retrospectively analyzed the clinical data of patients with ureteropelvic junction obstruction (UPJO) who underwent LP in our department from January 2016 to September 2020. For patients who developed a difficult process of inserting the DJ stent, the externalized uretero-pyelostomy (EUP) stent was indwelled. Patients were finally divided into two groups: DJ group and EUP group. The primary outcomes were recurrent UPJO, postoperative uretero-vesical junction obstruction (UVJO) and complications. Results A total of 535 patients were included in the study, of which 37 patients (6.9%) failed to insert the DJ stent. Age was younger, and weight was lower (P < 0.05) in the EUP group. Within follow-up, recurrent UPJO occurred in ten (1.87%) patients, nine in the DJ group and one in the EUP group (P > 0.05). The incidence of postoperative UVJO in the EUP group was significantly higher than in the DJ group (10.8% vs. 0.2%, P < 0.01). 74 patients (13.8%) developed complications after surgery, 12 patients (32.4%) in the EUP group, significantly higher than that in the DJ group (32.4% vs. 12.4%, P < 0.01). Compared with the DJ group, the larger APD were observed in the EUP group at three months postoperatively (3.50 [3.02;4.58] vs. 2.20 [1.50;2.88], P < 0.05), but the difference vanished in further follow-up. Conclusion The failure of DJ stent placement tends to occur in patients with younger age, lower weight, and larger preoperative APD. Failure may not increase the recurrent UPJO rate, but may indicate a higher probability of postoperative UVJO and may develop more postoperative complications and slower recovery.

Publisher

Springer Science and Business Media LLC

Subject

Urology,Reproductive Medicine,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3