Author:
Xiao Jie,Yu Haojun,Sui Xiuli,Liu Guobing,Cao Yanyan,Yanzhao Zhao,Zhang Yiqiu,Hu Pengcheng,Cheng Dengfeng,Shi Hongcheng
Abstract
Abstract
Background
The injection activity of tracer, acquisition time, patient-specific photon attenuation, and large body mass, can influence on image quality. Fixed acquisition time and body mass related injection activity in clinical practice results in a large difference in image quality. Thus, this study proposes a patient-specific acquisition time regimen of 68 Ga-DOTATATE total-body positron emission tomography-computed tomography (PET/CT) to counteract the influence of body mass (BM, kg) on image quality, and acquire an acceptable and constant image of patients with neuroendocrine tumors (NETs).
Methods
The development cohort consisting of 19 consecutive patients with full activity (88.7–204.9 MBq, 2.0 ± 0.1 MBq/kg) was to establish the acquisition time regimen. The liver SNR (signal-to-noise ratio, SNRL) was normalized (SNRnorm) by the product of injected activity (MBq) and acquisition time (min). Fitting of SNRnorm against body mass (BM, kg) in linear correlation was performed. Subjective assessment of image quality was performed using a 5-point Likert scale to determine the acceptable threshold of SNRL, and an optimized acquisition regimen based on BM was proposed, and validated its feasibility through the validation cohort of 57 consecutive NET patients with half activity (66.9 ± 11.3 MBq, 1.0 ± 0.1 MBq/kg) and a fixed acquisition time regimen.
Results
The linear correlation (R2 = 0.63) between SNRnorm and BM (kg) was SNRnorm = -0.01*BM + 1.50. The threshold SNRL of acceptable image quality was 11.2. The patient-specific variable acquisition time regimen was determined as: t (min) = 125.4/(injective activity)*(-0.01*BM + 1.50)2. Based on that proposed regimen, the average acquisition time for acceptable image quality in the validation cohort was 2.99 ± 0.91 min, ranging from 2.18 to 6.35 min, which was reduced by 36.50% ~ 78.20% compared with the fixed acquisition time of 10 min. Subjective evaluation showed that acceptable image quality could be obtained at 3.00 min in the validation group, with an average subjective score of 3.44 ± 0.53 (kappa = 0.97, 95% CI: 0.96 ~ 0.98). Bland–Altman analysis revealed good agreement between the proposed regimen and the fixed acquisition time cohort.
Conclusion
A patient-specific acquisition time regimen was proposed in NET patients in development cohort and validated its feasibility in patients with NETs in validation cohort by 68 Ga-DOTATATE total-body PET/CT imaging. Based on the proposed regimen, the homogenous image quality with optimal acquisition time was available independent of body mass.
Funder
Three-year Action Plan of Clinical Skills and Innovation of Shanghai Hospital Development Center
Science and Technology Committee of Shanghai Municipality
Special Fund for Clinical Research, Young Program of Zhongshan Hospital of Fudan University
Specialized Research Fund for the Doctoral Program of Higher Education of China
Shanghai Municipal Key Clinical Specialty Project
Next-generation information infrastructure construction project from Shanghai Municipal Commission of Economy and Informalization
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging,Oncology,General Medicine,Radiological and Ultrasound Technology
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献