Abstract
Abstract
Objectives
To assess the resectability of pancreatic ductal adenocarcinoma (PDAC), the evaluation of tumor vascular contact holds paramount significance. This study aimed to compare the image quality and diagnostic performance of high-resolution (HR) pancreas computed tomography (CT) using an 80 kVp tube voltage and a thin slice (1 mm) for assessing PDAC resectability, in comparison with the standard protocol CT using 120 kVp.
Methods
This research constitutes a secondary analysis originating from a multicenter prospective study. All participants underwent both the standard protocol pancreas CT using 120 kVp with 3 mm slice thickness (ST) and HR-CT utilizing an 80 kVp tube voltage and 1 mm ST. The contrast-to-noise ratio (CNR) between parenchyma and tumor, along with the degree of enhancement of the abdominal aorta and main portal vein (MPV), were measured and subsequently compared. Additionally, the likelihood of margin-negative resection (R0) was evaluated using a five-point scale. The diagnostic performance of both CT protocols in predicting R0 resection was assessed through the area under the receiver operating characteristic curve (AUC).
Results
A total of 69 patients (37 males and 32 females; median age, 66.5 years) were included in the study. The median CNR of PDAC was 10.4 in HR-CT, which was significantly higher than the 7.1 in the standard CT (P=0.006). Furthermore, HR-CT demonstrated notably higher median attenuation values for both the abdominal aorta (579.5 HU vs. 327.2 HU; P=0.002) and the MPV (263.0 HU vs. 175.6 HU; P=0.004) in comparison with standard CT. Following surgery, R0 resection was achieved in 51 patients. The pooled AUC for HR-CT in predicting R0 resection was 0.727, slightly exceeding the 0.699 of standard CT, albeit lacking a significant statistical distinction (P=0.128).
Conclusion
While HR pancreas CT using 80 kVp offered a notably greater degree of contrast enhancement in vessels and a higher CNR for PDAC compared to standard CT, its diagnostic performance in predicting R0 resection remained statistically comparable.
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging,Oncology,General Medicine,Radiological and Ultrasound Technology
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献