Objective
The present study aimed to evaluate the short-term clinical performance and safety of percutaneous microwave ablation (MWA) techniques for the treatment of bone tumors.
Methods
This single-institution retrospective study investigated 47 cases of bone tumors treated by MWA from June 2015 to June 2018. The study included 26 patients (55.3%) with benign bone tumors and 21 patients (44.7%) with malignant bone tumors. The tumors were located in the spine or sacrum (15, 31.9%), the upper extremities (6, 12.8%), the lower extremities (17, 36.2%) and the pelvis (9, 19.1%). Outcomes regarding clinical efficacy, including pain relief, quality of life, and intervention-related complications, were evaluated before and after MWA using the visual analog scale (VAS) and the 36-item Short-Form Health Survey (SF-36) scoring system.
Results
Of the 47 patients included in this study, all of them completed follow-up examinations, with a mean follow-up duration of 4.8 ± 1.6 months (range, 2–9 months). Significantly improved VAS and SF-36 scores were recorded after the initial treatment (P<0.001), suggesting that almost 100% of patients experienced pain relief and an improved quality of life following surgery. No major intervention-related complications (e.g., serious neurovascular injury or infection) occurred during or after the treatment. We recorded only three minor posttreatment complications (6.4%, 3/47), which were related to thermal injury that caused myofasciitis and affected wound healing.
Conclusion
In our study, the short-term efficacy of MWA was considerably favorable, with a relatively low rate of complications. Our results also showed that MWA was effective for pain relief and improved patients’ quality of life, making it a feasible treatment alternative for bone tumors.
Publisher
Springer Science and Business Media LLC
Subject
Radiology Nuclear Medicine and imaging,Oncology,General Medicine,Radiological and Ultrasound Technology
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献