Abstract
Abstract
Background
There is no consensus on 3-dimensional (3D) quantification method for solid component within part-solid nodules (PSNs). This study aimed to find the optimal attenuation threshold for the 3D solid component proportion in low-dose computed tomography (LDCT), namely the consolidation/tumor ratio of volume (CTRV), basing on its correlation with the malignant grade of nonmucinous pulmonary adenocarcinomas (PAs) according to the 5th edition of World Health Organization classification. Then we tested the ability of CTRV to predict high-risk nonmucinous PAs in PSNs, and compare its performance with 2-dimensional (2D) measures and semantic features.
Methods
A total of 313 consecutive patients with 326 PSNs, who underwent LDCT within one month before surgery and were pathologically diagnosed with nonmucinous PAs, were retrospectively enrolled and were divided into training and testing cohorts according to scanners. The CTRV were automatically generated by setting a series of attenuation thresholds from − 400 to 50 HU with an interval of 50 HU. The Spearman’s correlation was used to evaluate the correlation between the malignant grade of nonmucinous PAs and semantic, 2D, and 3D features in the training cohort. The semantic, 2D, and 3D models to predict high-risk nonmucinous PAs were constructed using multivariable logistic regression and validated in the testing cohort. The diagnostic performance of these models was evaluated by the area under curve (AUC) of receiver operating characteristic curve.
Results
The CTRV at attenuation threshold of -250 HU (CTRV− 250HU) showed the highest correlation coefficient among all attenuation thresholds (r = 0.655, P < 0.001), which was significantly higher than semantic, 2D, and other 3D features (all P < 0.001). The AUCs of CTRV− 250HU to predict high-risk nonmucinous PAs were 0.890 (0.843–0.927) in the training cohort and 0.832 (0.737–0.904) in the testing cohort, which outperformed 2D and semantic models (all P < 0.05).
Conclusions
The optimal attenuation threshold was − 250 HU for solid component volumetry in LDCT, and the derived CTRV− 250HU might be valuable for the risk stratification and management of PSNs in lung cancer screening.
Funder
National Natural Science Foundation of China
Sichuan Science and Technology Program
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging,Oncology,General Medicine,Radiological and Ultrasound Technology
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献