Author:
Barrigah-Benissan Koko,Ory Jerome,Simon Claire,Loubet Paul,Martin Aurelie,Beregi Jean-Paul,Lavigne Jean-Philippe,Sotto Albert,Larcher Romaric
Abstract
Abstract
Background
Despite their spread in daily practice, few data is available on clinical factors associated with peripherally inserted central catheter (PICC)-related bloodstream infections (PR-BSI). We aimed to assess the PR-BSI incidence, microbiology, and factors associated with PR-BSI with a focus on clinical symptoms.
Methods
We conducted a retrospective cohort study in a French university hospital. We screened all PICC insertions performed from April 1st, 2018, to April 1st, 2019, and included PICC insertions in adult patients. We assessed the PR-BSI incidence, the factors associated with PR-BSI using a Cox model, and negative and positive predictive values (NPVs and PPVs) of each clinical sign for PR-BSI.
Results
Of the 901 PICCs inserted in 783 patients (38,320 catheters days), 214 PICCs (24%) presented with a complication. The most prevalent complication was PR-BSI (1.9 per 1000 catheter days; 8.1% of inserted PICCs ). Enterobacterales (N = 27, 37%) and coagulase negative Staphylococci (N = 24, 33%), were the main microorganisms responsible for PR-BSI. Factors independently associated with occurrence of PR-BSI were fever (hazard ratio 13.21, 95% confidence interval 6.00–29.11, p < 0.001) and chills (HR 3.66, 95%CI 1.92–6.99, p < 0.001). All clinical signs and a duration of PICC maintenance ≥ 28 days, had a low PPVs (≤ 67.1%) but high NPVs (≥ 92.5%) for PR-BSI.
Conclusions
Monitoring of clinical signs, especially fever and chills, with caution and limitation of device maintenance duration, could improve PICC management.
Publisher
Springer Science and Business Media LLC
Subject
Pharmacology (medical),Infectious Diseases,Microbiology (medical),Public Health, Environmental and Occupational Health