The use of a UV-C disinfection robot in the routine cleaning process: a field study in an Academic hospital

Author:

Astrid Füszl,Beata Zatorska,Van den Nest Miriam ,Julia Ebner,Elisabeth PresterlORCID,Magda Diab-Elschahawi

Abstract

Abstract Background Environmental surface decontamination is a crucial tool to prevent the spread of infections in hospitals. However, manual cleaning and disinfection may be insufficient to eliminate pathogens from contaminated surfaces. Ultraviolet-C (UV-C) irradiation deploying autonomous disinfection devices, i.e. robots, are increasingly advertised to complement standard decontamination procedures with concurrent reduction of time and workload. Although the principle of UV-C based disinfection is proven, little is known about the operational details of UV-C disinfection delivered by robots. To explore the impact of a UV-C disinfection robot in the clinical setting, we investigated its usability and the effectiveness as an add-on to standard environmental cleaning and disinfection. Additionally, its effect on Candida auris, a yeast pathogen resistant to antifungals and disinfectants, was studied. Methods After setting the parameters “surface distance” and “exposure time” for each area as given by the manufacturer, the robot moved autonomously and emitted UV-C irradiation in the waiting areas of two hospital outpatient clinics after routine cleaning and/or disinfection. To quantify the efficacy of the robotic UV-C disinfection, we obtained cultures from defined sampling sites in these areas at baseline, after manual cleaning/disinfection and after the use of the robot. Four different C. auris strains at two concentrations and either in a lag or in a stationary growth phase were placed in these areas and exposed to UV-C disinfection as well. Results The UV-C irradiation significantly reduced the microbial growth on the surfaces after manual cleaning and disinfection. C. auris growth in the lag phase was inhibited by the UV-C irradiation but not in the presence of the rim shadows. The effects on C. auris in the stationary phase were differential, but overall C. auris strains were not effectively killed by the standard UV-C disinfection cycle. Regarding usability, the robot’s interface was not intuitive, requiring advanced technical knowledge or intensive training prior to its use. Additionally, the robot required interventions by the technical operator during the disinfection process, e.g. stopping due to unforeseen minor dislocation of items during the clinical service or due to moving individuals, making it a delicate high-tech device but not yet ready for the autonomous use in the clinical routine. Conclusions Presently, the UV-C robot tested in this study is not ready to be integrated in the environmental cleaning and disinfection procedures in our hospital. The single standard disinfection UV-C irradiation cycle is not sufficient to inactivate pathogens with augmented environmental resilience, e.g. C. auris, particularly when microbial loads are high.

Publisher

Springer Science and Business Media LLC

Subject

Pharmacology (medical),Infectious Diseases,Microbiology (medical),Public Health, Environmental and Occupational Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3