Abstract
Abstract
Background
The objective of this study was to determine the level of environmental contamination in hospitals in the Dutch/Belgian border area, using ATP measurements.
Design
A cross-sectional observational survey.
Methods
Standardized ATP measurements were conducted in 9 hospitals on 32 hospital wards. Thirty pre-defined surfaces per hospital ward were measured with the 3 M Clean Trace NG luminometer. Results are displayed in relative light units (RLU). RLU > 1000 was considered as “not clean.” Differences in RLU values were compared between countries, hospitals, fomite groups and medical specialties.
Results
A total of 960 ATP measurements were performed, ranging from 60 up to 120 per hospital. The median RLU-value was 568 (range: 3–277,586) and 37.7% of the measurements were rated as not clean (RLU > 1000). There were significant differences between countries, hospitals and fomite groups.
Conclusion
ATP measurements can be used as a more objective approach to determine the level of environmental contamination in hospitals. Significant differences in ATP levels were found between hospitals and between countries. Also, substantial differences were found between different fomite groups. These findings offer potential targets for improvement of cleanliness in healthcare facilities.
Funder
Interreg
ERDF
Rijksinstituut voor Volksgezondheid en Milieu
Dutch Ministry of Economic Affairs
Provincie Noord-Brabant
Belgian Department of Agriculture and Fisheries
Province of Antwerp, Belgium
Province of East-Flanders, Belgium
3M
Publisher
Springer Science and Business Media LLC
Subject
Pharmacology (medical),Infectious Diseases,Microbiology (medical),Public Health, Environmental and Occupational Health
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献