Abstract
Abstract
Background
The aim of this cadaver study was to evaluate an original technique for measuring posterior tibial translation based on an angle value instead of a distance value, with and without posterior stress application. It was hypothesized that an angle measurement of the posterior tibial translation would confirm the presence of a PCL tear with the knee flexed and completely extended.
Method
Using fresh cadavers, a set of strict lateral views were taken by fluoroscopy with the knee at 0°, 45° and 90° flexion on the intact knee and after transecting the PCL. The primary endpoint was the change in the posterior translation measured using a new technique, the ABC angle. This measurement was compared to the conventional posterior translation distance measurement with and without a posterior stress placed on the knee.
Results
Application of a posterior stress revealed clear changes in posterior translation after PCL transection with the knee at 0° for the angle technique and at 45° and 90° for the two techniques (p < 0.05). Contrary to the reference method, the ABC angle method found a statistically significant difference in posterior translation with the knee in extension.
Conclusion
Our technique provides a reliable radiographic measurement of posterior translation with the knee in extension, which should make it easier to acquire radiographs in patients who have pain with knee flexion. This angular measurement also has the advantage of not needing length calibration contrary to the reference technique.
Level of evidence
IV
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine
Reference15 articles.
1. Kumagai M, Mizuno Y, Mattessich SM, Elias JJ, Cosgarea AJ, Chao EY (2002) Posterior cruciate ligament rupture alters in vitro knee kinematics. Clin Orthop 241–248. https://doi.org/10.1097/00003086-200202000-00029
2. Jacobsen K (1976) Stress radiographical measurement of the anteroposterior, medial and lateral stability of the knee joint. Acta Orthop Scand 47:335–334
3. Jacobsen K (1981) Gonylaxometry. Stress radiographic measurement of passive stability in the knee joints of normal subjects and patients with ligament injuries. Accuracy and range of application. Acta Orthop Scand Suppl 194:1–263
4. Makris CA, Georgoulis AD, Papageorgiou CD, Moebius UG, Soucacos PN (2000) Posterior cruciate ligament architecture: evaluation under microsurgical dissection. Arthroscopy 16:627–632. https://doi.org/10.1053/jars.2000.9238
5. Edwards A, Bull AMJ, Amis AA (2007) The attachments of the fiber bundles of the posterior cruciate ligament: an anatomic study. Arthroscopy 23:284–290. https://doi.org/10.1016/j.arthro.2006.11.005
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献