On the value and limitations of incorporating a “clean phase” into the surgical treatment of prosthetic joint infections – an illustrative cadaveric study using fluorescent powder

Author:

Vles GeorgesORCID,Bossen Jeroen,Kloos Johannes,Debeer Philippe,Ghijselings Stijn

Abstract

Abstract Purposes A septic revision of an artificial joint is routinely split up in a so-called dirty phase and a clean phase. The measures taken to initiate the start of the clean phase vary significantly between musculoskeletal infection centers. We performed simulations of one-step exchanges of infected THAs and sought to 1) determine the effect of different clean phase protocols on the sterile field, and 2) determine whether or not it is possible to re-implant the new prosthesis completely clean. Methods Nine fresh frozen cadaveric hips were used and primary THA was undertaken via a direct anterior approach. Before implantation of the components varying amounts of fluorescent powder (GloGerm) were deposited, simulating bacterial infection. Second, a one-step exchange was performed via a posterolateral approach. After implant removal, debridement, and lavage, randomization determined which clean phase protocol was followed, i.e. no, some or full additional measures. Finally, the new prosthesis was re-implanted. In order to determine the effect of different clean phase protocols on contamination of the sterile field standardized UV light-enhanced photographs were obtained of 1) the gloves, 2) the instrument table, 3) the drapes, and 4) the wound and these were ranked on cleanliness by a blinded panel of hip surgeons. In order to determine whether or not it is possible to re-implant the prosthesis completely clean, the implant was taken out again at the end of the one-step exchange and inspected for contamination under UV light. Results The gloves, the instrument table, the drapes and the wound were significantly cleaner after a clean phase using full additional measures compared to partial or no additional measures (p < 0.000). Partial measures were able to reduce some of the contamination of the gloves and the wound, but had no effect on the drapes and the instrument table. All re-implanted implants were contaminated with some amount of fluorescent powder at the end of the one-step exchange. Conclusions We advise to incorporate a clean phase with full additional measures into the surgical treatment of prosthetic joint infections, as partial measures seem to be a poor compromise. Level of evidence Not applicable (cadaveric study).

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3