Difference in implant design affects midflexion rotational laxity in cruciate-retaining total knee arthroplasty: a computer navigation study

Author:

Tsuda Takashi,Hino KazunoriORCID,Kutsuna Tatsuhiko,Watamori Kunihiko,Kinoshita Tomofumi,Takao Masaki

Abstract

Abstract Purpose This study aimed to compare midflexion rotational laxity between two different design concept models of cruciate-retaining total knee arthroplasty: symmetrical surface design of neutral joint line obliquity and asymmetrical surface design of varus joint line obliquity. Methods Sixty-three knees that underwent cruciate-retaining total knee arthroplasty were evaluated. Manual maximum passive rotational stress without acceleration was applied to the knees under navigation monitoring. Pre-operative and post-operative internal and external rotational angles were measured at 30°, 45°, 60°, and 90° knee flexion. Results The post-operative internal rotational laxity was significantly increased compared with pre-operative levels at 30°, 45°, 60°, and 90° flexion among all subjects (mean 9.7° vs 11.1°, 10.6° vs 11.6°, 11.2° vs 12.9°, and 13.2° vs 14.9°; p = 0.01, 0.04, 0.001, and 0.008, respectively). The post-operative external rotational laxity was significantly decreased compared to pre-operative levels at 30°, 45°, 60°, and 90° flexion among all subjects (mean 10.8° vs 6.8°, 12.5° vs 9.4°, 12.8° vs 10.0°, and 11.3° vs 9.5°; p < 0.0001, < 0.0001, < 0.0001, and 0.0008, respectively). The post-operative total rotational laxity significantly decreased, compared with pre-operative levels, at 30° and 45° flexion among all subjects (mean 20.4° vs 17.9°, and 23.1° vs 21.1°; p = 0.002 and 0.04, respectively). The post-operative total rotational laxity was significantly smaller in asymmetrically designed total knee arthroplasty than in symmetrically designed total knee arthroplasty at 30°, 45°, and 60° flexion (mean 19.3° vs 15.8°, 22.8° vs 18.7°, and 24.4° vs 20.8°; p = 0.03, 0.03, and 0.02, respectively), whereas no significant difference was observed at 90° flexion. Conclusion Compared to symmetrical surface design, asymmetrical surface design resulted in lower rotational laxity at the midflexion range in cruciate-retaining total knee arthroplasty. Level of evidence III.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3