Factors affecting aseptic loosening in primary total knee replacements: an in vitro study

Author:

Lionberger DavidORCID,Wattenbarger Laura,Conlon Christopher,Walker Timothy J.

Abstract

Abstract Background Implant surface integrity and cement bonding are assumed to be sufficient in primary total knee replacements to stabilize implants for extended wear without concerns over delamination and loosening. Yet there exists a significant rate of aseptic loosening where failure at implant cement interface occurs. The aim of this study is to look at specific aspects leading to aseptic loosening of the total knee replacement, where cement adhesion to the implant results in the lowest pull off strength. Methods Virgin ceramic coated and uncoated chrome cobalt tibial trays were used in a pull off study using differing viscosities of cement at varied time intervals to compare which combination is strongest compared to which is least resistant to pull off testing. Results Low viscosity cement had a 44% (5.9 kg verses 3.3 kg, p < 0.001) higher pull-off strength compared to high viscosity cement. Coated implants had a 30% (3.9 kg verses 5.5 kg, p = 0.037) lower pull-off strength compared to non-coated. Testing measures were limited to cement utilization less than 5 minutes due to the poor adhesion of the dowels beyond this time. Finally, there was a significant difference in adhesion properties between brand names when utilizing low viscosity cement on the non-coated trays (10.34 kg for Simplex verses 4.87 for Palacos, p = 0.021). Conclusion There are differences in adhesion properties between cement vendors, prompting significant concerns over the use of coated implants with particular cement types. Use of low viscosity cement on non-coated surfaces in the early liquid phase of cement curing was found to produce the best chance for adequate adhesion. This study demonstrates that there is variation in the adhesive properties of implants utilized in total knee replacements, and that the orthopedic community should consider not only the implant, cement, and curing time individually, but the overall integrity conferred from the combination of all of these variables.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine

Reference27 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3