Abstract
Abstract
Purpose
The aim of the study was to directly measure graft forces of an anterior cruciate ligament reconstruction (ACLR) and a lateral extra-articular tenodesis (LET) using the modified Lemaire technique in combined anterior cruciate ligament (ACL) deficient and anterolateral rotatory instable knees and to analyse the changes in knee joint motion resulting from combined ACLR + LET.
Methods
On a knee joint test bench, six fresh-frozen cadaveric specimens were tested at 0°, 30°, 60°, and 90° of knee flexion in the following states: 1) intact; 2) with resected ACL; 3) with resected ACL combined with anterolateral rotatory instability; 4) with an isolated ACLR; and 5) with combined ACLR + LET. The specimens were examined under various external loads: 1) unloaded; 2) with an anterior tibial translation force (ATF) of 98 N; 3) with an internal tibial torque (IT) of 5 Nm; and 4) with a combined internal tibial torque of 5 Nm and an anterior tibial translation force of 98 N (IT + ATF). The graft forces of the ACLR and LET were recorded by load cells incorporated into custom devices, which were screwed into the femoral tunnels. Motion of the knee joint was analysed using a 3D camera system.
Results
During IT and IT + ATF, the addition of a LET reduced the ACLR graft forces up to 61% between 0° and 60° of flexion (P = 0.028). During IT + ATF, the LET graft forces reached 112 N. ACLR alone did not restore native internal tibial rotation after combined ACL deficiency and anterolateral rotatory instability. Combined ACLR + LET was able to restore native internal tibial rotation values for 0°, 60° and 90° of knee flexion with decreased internal tibial rotation at 30° of flexion.
Conclusion
The study demonstrates that the addition of a LET decreases the forces seen by the ACLR graft and reduces residual rotational laxity after isolated ACLR during internal tibial torque loading. Due to load sharing, a LET could support the ACLR graft and perhaps be the reason for reduced repeat rupture rates seen in clinical studies. Care must be taken not to limit the internal tibial rotation when performing a LET.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine
Reference44 articles.
1. Claes S, Bartholomeeusen S, Bellemans J (2014) High prevalence of anterolateral ligament abnormalities in magnetic resonance images of anterior cruciate ligament-injured knees. Acta Orthop Belg 80:1–2014
2. Musahl V, Rahnemai-Azar AA, Costello J, Arner JW, Fu FH, Hoshino Y et al (2016) The influence of meniscal and anterolateral capsular injury on knee laxity in patients with anterior cruciate ligament injuries. Am J Sports Med 44:3126–3131
3. Van Dyck P, Clockaerts S, Vanhoenacker FM, Lambrecht V, Wouters K, De Smet E et al (2016) Anterolateral ligament abnormalities in patients with acute anterior cruciate ligament rupture are associated with lateral meniscal and osseous injuries. Eur Radiol 26:3383–3391
4. Yoshida M, Herbst E, Albers M, Musahl V, Fu FH, Onishi K (2017) The anterolateral complex in anterior cruciate ligament deficient knees demonstrate sonographic abnormalities on high-resolution sonography. Knee Surg Sports Traumatol Arthrosc 25:1024–1029
5. Amis AA, Scammell BE (1993) Biomechanics of intra-articular and extra-articular reconstruction of the anterior cruciate ligament. J Bone Joint Surg Br 75:812–817
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献