How reproducible are clinical measurements in robotic knee surgery?

Author:

Matassi Fabrizio,Bori Edoardo,Giabbani Niccolò,Civinini Roberto,Innocenti Bernardo

Abstract

Abstract Purpose Robotic-assisted surgery has been recently introduced to improve biomechanical restoration, and thus better clinical and functional outcomes, after knee joint arthroplasty operations. Robotic-assisted uni-compartmental knee arthroplasty (UKA) aims indeed to improve surgical bone resection and alignment accuracy, optimized component positioning and knee balancing, relying on a series of calibration measurements performed during the surgery. These advantages focus therefore on improving the reproducibility of UKA surgeries, reducing (if not eliminating) eventual differences among high- and low-volume surgeons. The purpose of this study is to investigate and quantify the reproducibility of in-vivo measurements performed with a robotic system: the intra- and inter-observer variability of a series of measurements was therefore analyzed and compared among differently experienced operators. Methods Five patients were analyzed and underwent robotic-assisted UKA using a semi-active robotic system. Three different observers with different experience levels were involved to independently perform the measurements of two parameters of the preoperative knee (Hip-Knee-Ankle angle [HKAa], Internal-External Rotation) at different degrees of knee flexion. Inter-observer and intra-observer comparisons were performed. Results The average variability in the measurements obtained from the intra-observer and inter-observer comparisons were always < 0.68° for HKAa and < 2.59° for internal-external rotation, and the ICCs showed excellent agreement (> 0.75) for most cases and good agreement (> 0.60) in the remaining ones. Conclusion This study demonstrated high reproducibility of the measurements obtainable in clinical environment with the robotic system. The inter-observer results furthermore showed that the level of confidence with the robotic system is not significantly influencing the measurement.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3