The personalized Berger method is usable to solve the problem of tibial rotation

Author:

András Gömöri,Németh Gábor,Oláh Csaba Zsolt,Lénárt Gábor,Drén Zsanett,Papp Miklós

Abstract

Abstract Purpose The revision of any total knee replacement is carried out in a significant number of cases, due to the excessive internal rotation of the tibial component. The goal was to develop a personalized method, using only the geometric parameters of the tibia, without the femoral guidelines, to calculate the postoperative rotational position of tibial component malrotation within a tolerable error threshold in every case. Methods Preoperative CT scans of eighty-five osteoarthritic knees were examined by three independent medical doctors twice over 7 weeks. The geometric centre of the tibia was produced by the ellipse annotation drawn 8 mm below the tibial plateau, the sagittal and frontal axes of the ellipse were transposed to the slice of the tibial tuberosity. With the usage of several guide lines, a right triangle was drawn within which the personalized Berger angle was calculated. Results A very good intra-observer (0.89-0.925) and inter-observer (0.874) intra-class correlation coefficient (ICC) was achieved. Even if the average of the personalized Berger values were similar to the original 18° (18.32° in our case), only 70.6% of the patients are between the clinically tolerable thresholds (12.2° and 23.8°). Conclusion The method, measured on the preoperative CT scans, is capable of calculating the required correction during the planning of revision arthroplasties which are necessary due to the tibial component malrotation. The personalized Berger angle isn’t altered during arthroplasty, this way it determines which one of the anterior reference points of the tibia (medial 1/3 or the tip of the tibial tuberosity, medial border or 1/6 or 1/3 or the centre of the patellar tendon) can be used during the positioning of the tibial component. Level of evidence Level II, Diagnostic Study (Methodological Study).

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3