Measurements of bone tunnel size in anterior cruciate ligament reconstruction: 2D versus 3D computed tomography model

Author:

Crespo Bernardo,Aga Cathrine,Wilson Katharine J,Pomeroy Shannon M,LaPrade Robert F,Engebretsen Lars,Wijdicks Coen A

Abstract

Abstract Background Revision anterior cruciate ligament (ACL) reconstruction requires a precise evaluation of previous tunnel locations and diameters. Enlargement of the tunnels, despite not usually affecting primary reconstruction outcomes, plays an important role in revision ACL management. Three dimensional (3D) computed tomography (CT) models are reported to be the most accurate method for identifying the tunnel position and possible conflicts with a revision tunnel placement. However, the ability of 3D CT to measure the tunnel size is still not proven. The goal of this study was to evaluate the ability of measuring the size of the bone tunnels in ACL reconstructed knees with 3D CT compared to the traditional two dimensional (2D) CT method. Methods Twenty-four patients had CT scans performed immediately following ACL reconstruction surgery. Their femoral tunnels size were measured by a standard 2D CT measurement and then compared with three novel 3D CT measuring methods: the best transverse section method, the best fit cylinder method and the wall thickness method. The drill size used during surgery was used as a control measure for the tunnel width. Intra-class correlation coefficients were obtained. Results The intra-class correlation coefficient and respective 95% confidence interval range (ICC [95%CI]) for the three methods compared with the drill sizes were 0.899 [0.811-0.947] for the best transverse section method, 0.745 [0.553-0.862] for the best fit cylinder method, −0.004 [−0.081 to −0.12] for the wall thickness method and 0.922 [0.713-0.97] for the 2D CT method. The mean differences compared to the drill size were 0.02 mm for the best fit transverse section method, 0.01 mm for the best fit cylinder diameter method, 3.34 mm for the wall thickness method and 0.29 mm for the 2D CT method. The intra-rater agreement (ICC [95%CI]) was excellent for the best transverse section method 0.999 [0.998-0.999] and the 2D CT method 0.969 [0.941-0.984]. Conclusions The 3D best transverse section method presented a high correlation to the drill sizes and high intra-rater agreement, and was the best method for ACL tunnel evaluation in a 3D CT based model.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3