Author:
Cai Jianzhi,Huang Haitao,Zhou Yongxin,Mei Yunqing,Shao Jie,Wang Yongwu
Abstract
Abstract
Background
To evaluated the feasibility and safety of new aortic valved stents in transcatheter aortic valve implantation (TAVI) using retrograde approach by in vitro testing and animal implantation.
Materials and Methods
The fluid passing test, expanding and releasing tests, static and releasing tests in tube were performed for new valved stents. Transvalvular pressure gradient, effective orifice area, pre-implantation and post-implantation regurgitant volume for the new stents were detected. Then, the new stents were implanted in six pigs using retrograde approach. These pigs were euthanized 12 h after the implantation for anatomic evaluation.
Results
In vitro tests showed that the closure of the new stents leaflets were effective, and stents could be released through catheter, then expanded completely and fixed fast in the tube. The coronary artery flow rates did not changed significantly after implantation (P > 0.05), while aortic regurgitant volumes were obviously reduced (P < 0.05). No significant difference in the transvalvular pressure gradient and effective orifice area of the new stents implanted within or above the valve leaflets was found (P > 0.05). In vivo experiments indicated that TAVI was successfully performed in six pigs using retrograde approach. However, one pig was died 10 h after the implantation since the stent was not expanded completely. The leaflets in stents were opening well and no valvular regurgitation was observed in the other five pigs. And thrombosis was not found.
Discussion and Conclusion
The new type of aortic valved stent designed in this study was characterized with good stability and could avoid the impact caused by valve leaflets on the coronary artery.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine
Reference32 articles.
1. Altowaijri A, Phillips CJ, Fitzsimmons D: A systematic review of the clinical and economic effectiveness of clinical pharmacist intervention in secondary prevention of cardiovascular disease. J Manag Care Pharm. 2013, 19: 408-416.
2. Davis EM, Knezevich JT, Teply RM: Advances in antiplatelet technologies to improve cardiovascular disease morbidity and mortality: a review of ticagrelor. Clin Pharmacol. 2013, 5: 67-83.
3. Nishimura RA: Cardiology patient pages Aortic valve disease. Circulation. 2002, 106: 770-772. 10.1161/01.CIR.0000027621.26167.5E.
4. Baan J, Yong ZY, Koch KT, Henriques JP, Bouma BJ, de Hert SG, van der Meulen J, Tijssen JG, Piek JJ, de Mol BA: Percutaneous implantation of the CoreValve aortic valve prosthesis in patients at high risk or rejected for surgical valve replacement: clinical evaluation and feasibility of the procedure in the first 30 patients in the AMC-UvA. Neth Heart J. 2010, 18: 18-24.
5. Varadarajan P, Kapoor N, Bansal RC, Pai RG: Clinical profile and natural history of 453 nonsurgically managed patients with severe aortic stenosis. Ann Thorac Surg. 2006, 82: 2111-2115. 10.1016/j.athoracsur.2006.07.048.