Monitoring of oxidative and metabolic stress during cardiac surgery by means of breath biomarkers: an observational study

Author:

Pabst Florian,Miekisch Wolfram,Fuchs Patricia,Kischkel Sabine,Schubert Jochen K

Abstract

Abstract Background Volatile breath biomarkers provide a non-invasive window to observe physiological and pathological processes in the body. This study was intended to assess the impact of heart surgery with extracorporeal circulation (ECC) onto breath biomarker profiles. Special attention was attributed to oxidative or metabolic stress during surgery and extracorporeal circulation, which can cause organ damage and poor outcome. Methods 24 patients undergoing cardiac surgery with extracorporeal circulation were enrolled into this observational study. Alveolar breath samples (10 mL) were taken after induction of anesthesia, after sternotomy, 5 min after end of ECC, and 30, 60, 90, 120 and 150 min after end of surgery. Alveolar gas samples were withdrawn from the circuit under visual control of expired CO2. Inspiratory samples were taken near the ventilator inlet. Volatile substances in breath were preconcentrated by means of solid phase micro extraction, separated by gas chromatography, detected and identified by mass spectrometry. Results Mean exhaled concentrations of acetone, pentane and isoprene determined in this study were in accordance with results from the literature. Exhaled substance concentrations showed considerable inter-individual variation, and inspired pentane concentrations sometimes had the same order of magnitude than expired values. This is the reason why, concentrations were normalized by the values measured 120 min after surgery. Exhaled acetone concentrations increased slightly after sternotomy and markedly after end of ECC. Exhaled acetone concentrations exhibited positive correlation to serum C-reactive protein concentrations and to serum troponine-T concentrations. Exhaled pentane concentrations increased markedly after sternotomy and dropped below initial values after ECC. Breath pentane concentrations showed correlations with serum creatinine (CK) levels. Patients with an elevated CK-MB (myocardial&brain)/CK ratio had also high concentrations of pentane in exhaled air. Exhaled isoprene concentrations raised significantly after sternotomy and decreased to initial levels at 30 min after end of ECC. Exhaled isoprene concentrations showed a correlation with cardiac output. Conclusion Oxidative and metabolic stress during cardiac surgery could be assessed continuously and non-invasively by means of breath analysis. Correlations between breath acetone profiles and clinical conditions underline the potential of breath biomarker monitoring for diagnostics and timely initiation of life saving therapy.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 75 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3