Author:
Zhibing Qiu,Xin Chen,Ming Xu,Lele Liu,YingShuo Jiang,LiMing Wang
Abstract
Abstract
Background
There is controversy regarding the choice of prosthetic valves in patients with cardiac valve disease and dialysis-dependent patients. This review assesses a 12-year experience and outcomes after valve replacement in patients on chronic preoperative renal dialysis, comparing survival and valve-related outcomes following valve replacement with bioprostheses versus mechanical prostheses in this population in china.
Methods
From January 1999 and October 2011, 73 consecutive dialysis patients underwent cardiac valve replacement. The patients were divided into two groups: (Group B) bioprosthesis valves were implanted in 38 (52.1%) patients and (Group M) mechanical valves were implanted in 35 (47.9%) patients. Outcome measures included perioperative data, hospital mortality, major postoperative complications, follow-up outcomes, valve related morbidity and late survival.
Results
There were no significant differences in terms of patient characteristics in the 2 groups. Thirty-three were isolated aortic valve replacements (45.2%); 28 were isolated mitral valve replacements (38.4%); 10 were combined aortic and mitral replacements (13.7%); 2 were combined tricuspid and mitral replacements (2.7%). The overall hospital mortality was 5.5% (n = 4) and was not different between Group B (5.3%) and Group M (5.7%). Low ejection fraction was the only independent predictors of hospital mortality. There was no significant difference between the groups in the overall rate of complications. The overall mean follow-up was 47 ± 23 months. According to the Kaplan-Meier analysis, late mortality, perivalvular leak and freedom from reoperation were similar in patients with mechanical and bioprosthesis valves. The bioprosthesis valve group had significantly higher freedom from thromboembelism-bleeding events (100% versus 77.6 ± 11.0%, p = 0.012), and valve-related morbidity (73.2 ± 10.1% versus 58.1 ± 10.9%, p = 0.035) in 5 years. Kaplan–Meier survival estimates at 1, 3, and 5 years were 0.971, 0.832, and 0.530 in group B, and 0.967, 0.848, and 0.568 in group M.
Conclusions
There is no significant difference in the perioperative morbidity and mortality, late survival of dialysis patients after cardiac valve replacement with bioprostheses versus mechanical valves. In spite of the limited sample size analyzed, its outcome and consistency to several previous reports supports a conclusion that bioprostheses rather than mechanical ones could be a favorable choice for valve replacement needs of renal failure patients.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine
Reference22 articles.
1. US Renal Data System—Annual Data Report: National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases. 2001,http://www.usrds.org/adr.htm,
2. United States Renal Data System: USRDS 2000 Annual Data Report. 2000, Bethesda, Md: The National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases, 589-684.
3. Mehta S, Pae WE: Complications of cardiac surgery. Cardiac surgery in the adult. Edited by: Edmunds LH. 1997, New York: McGraw-Hill, 388-
4. Ko W, Krieger KH, Isom W: Cardiopulmonary bypass procedures in dialysis patients. Ann Thorac Surg. 1993, 55: 677-684. 10.1016/0003-4975(93)90275-M.
5. Lucke JC, Samy RN, Atkins BZ: Results of valve replacement with mechanical and biological prostheses in chronic renal dialysis patients. Ann Thorac Surg. 1997, 64: 129-132. 10.1016/S0003-4975(97)00342-1.
Cited by
16 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献